My ge zoneline heater won't blow hot air when in the heater position. The air conditioner however, works just fine. This thing was installed brand new into my apartment less than a year ago.


Answers :

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

My ge zoneline heater won't blow hot air when in the heater position. The air conditioner however, works just fine. This thing was installed brand new into my apartment less than a year ago.


... GE Zoneline AZ28E12DAB Heat Cool Air Conditioner

Daewoo DOZ-1206G Brand new, just installed. This replaced an older a.c. unit in our apartment that was not blowing any cold air. The technician said that one was broken and replaced it with this one. Once it was installed, the technician turned it on and left. After 5 minutes with it set at 16 degrees celsius the cool air (which was never freezing) just became normal air. We have tried everything on the controls, we cannot get it to cool our very small studio apartment. We live in Sth Korea by t


... Air Conditioners

I bought a home built in 1935 with a Perfection Brand gas forced air heater, any info or a website on this old brand of heater would be greately appreciated. I was told it is over 25 years old, I just want to read about this heater and get to know how it works, until I get money to purchase a new one. Thanks in advance.


Any and i mean any ac and heat company you call in the yellow pages can and will be happy to repair yor heater. parts are all generic. problem is the heat exchanger needs to be tested every year with a co detector so no one gets killed. thats pretty ... Air Conditioners

We had a brand new unit put in a couple of years back. When it was installed it worked. Once winter came, it obviously was turned off. Then the following summer, it would turn on but just blow air, would not cool at all- so the unit installers came out and repaired it. It worked through the summer, then the following summer-it wouldnt cool again-they came back out and fixed it again. Third summer in a row-it is not working again!! A friend told me this morning, on new units there is a


Yes but you should have to keep resteting it you might have a major problem are you beiing charge for freon if so you have a bad condensor unit (it have a leak ) check your bill if the same thing happens again go see what the techs are doing ... Honeywell Air Conditioners

NO COOLING I HAVE A LESS THAN 2 YEARS OLD AIR CONDITIONING (MODEL#FA4BNF036) THAT HAS STOPPED COOLING. I SEE NO LEAK AND HAS BRAND NEW FILTER. IT'S A SINGLE UNIT FOR CONDOMINIUMS. i THINK THAT THERE SHOULD BE A WARRANTY STILL, BUT TO GET TO SERVICE IS BEING A PAIN. CAN ANYONE PLS GIVE ME AN IDEA HOW TO GET IT WORKING AGAIN? tHANK YOU


If you feel the fan running specially the fan thats outside,that means the thermostat is sending the signal for cooling, if your compressor fails, what it will do it will get very hot!!! to the point that it will shut its self off, for safety, (Inte ... Carrier 38BRC048 Air Conditioner

I am renting an apartment that has 3 Singer Conditioners installed in the exterior walls of the unit. They appear to be at least 30 years old (and may be 40+ years old). The main unit (for heating and cooling all but the 2 bedrooms) broke down. The landlord is out-of-state, so we took care of getting it repaired. It needed a new motor. After the unit was installed with the new motor (and a cleaning), it emitted a foul, unbearable odor. I made the repair company come back and rinse the unit


This sounds as though you have a temperature control problem and you need to change the control.If the company that did the service will not return tell them an Attorney will be notified. ... Air Conditioners

Keeps freezing We installed a brand new Goodman Condensing Unit, Model #GSX130481, Serial #1304691511 and installed a new coil, Model #96-8W4N-0p/96-8, Serial #M0425130485 (Mortex Brand)in the existing Air Handler. The unit keeps freezing up. Can you give any insight on what might be the problem?


Low air flow or low on refrigerant. ... Goodman Air Conditioners

Hi, I had a Cozy gas-fired room heater installed two years ago. It has only been used during the winter months. When it was installed , it passed the carbon monoxide test (0 parts per million). I had it checked today, and it failed the test, and the gas specialist said it might have to be condemned. Also, he said that 5 of 6 similar Cozy heaters that were fairly new failed testing this season. Have you heard about Cozy heaters having a similar problem? What can I do? Model: VC351A-H 3


Hi,A very common problem with the unvented heaters is that they get dust and dirt in them and then they do not burn right. The pilot is especially bad and often that will make them burn bad failing the test.Before throwing it out I would ... Air Conditioners

Problem with a water dripping Air Conditioner.. I bought a New Plasm Aire Conditioner, Model Number: 580.750652500 last year and it was working great. Now this year I installed it and it continues to drip water from the front of the unit all the time and on all the mode settings. What is wrong with it and how can I stop it from dripping?


You need to reposition it to where the rear of the unit is tilted slightly down. So that the water will run down and out the rear. ... Kenmore 75051 Wall/Window Air Conditioner

In 2002, I had an Amana heat pump installed, in 2003, I had to have the defrost panel replaced and in April 2004, I had to have a new air handler installed, I'm not sure how many service calls I have had, but last year 2010, I had 3 calls at a cost of over $300, plus a new compressor, last week it ran and ran and did not heat my house at all. After several calls to the company they finally came and said the compressor was bad, it was replaced on Friday 4/8/2011, the weather was mild and I did n


I would contact Goomman manufacturing directly and explain the problem.\015\012remember tne product is only as good as the installer.\015\012this should not be happening to you and i'am sure Goodman will help you\015\012with this. ... Amana Air Conditioners

Problem with a water dripping Air Conditioner.. I bought a New Plasm Aire Conditioner, Model Number: 580.750652500 last year and it was working great. Now this year I installed it and it continues to drip water from the front of the unit all the time and on all the mode settings. What is wrong with it and how can I stop it from dripping?


THE "DRIPPING" is normal but The Unit Must be TILTED Towards the OUTSIDE SO THE cONDENSATION CAN drain OUTSIDE ... Kenmore 76100 Wall/Window Air Conditioner

I have a 24,500 BTU LG installed in my window. The unit works wonderful when it actually cuts on, its brand new, and is able to drain, and installed per the instructions. The unit stays on all the time, but will only cool for 5-10 minutes at a time, the rest is just the fan running with no cool air, just normal temperature air. What am i missing?


Possible bad thermostat. ... LG Heat cool Window Air Conditioner

I have/had 2 GE 8000btu wall air conditioners and at 3 years old, both of them within 2 weeks of each other had stopped blowing out cold air, just now the way a fan would blow. It almost seems to me that GE has purposely made these air conditioners to stop working properly at a certain time so I should buy new ones. I replaced one of them already with another brand, now I have to replace a 2nd one. I can't really afford to do this. Is it possible that they have both run out of Freon? Otherwise I


I doubt the freon would be gone its a sealed system unless someone was pokin the coils kids love to bend the fins for some reason could need a capacitor is the compressor starting ? humming ?running ... GE AJCQ08ACB Air Conditioner

I have a newer Bryant 340aav furnace that came w/a new house I had built not even 3 years ago. The house was completed at the end of November & come the next spring it was discovered the installation crew never put freon into the a/c. Fast forward to 2 years after that (March of 2012) I went to turn on my a/c to discover it was just blowing lukewarm air. Had the crew come out again & put in almost 2 lbs of freon. The technician insisted he checked for leaks & found none so I paid him his service


... Air Conditioners

Our mainboard VB109B3150, and BZ102B9003 of our AmcorAire mini split units went out this summer. Both were less than a year old and one had only recently been installed in our new house. I called about replacement parts and was told not till after Labor Day would they be available. I need to order either parts to fix them or new mainboards.


We stock a complete line of parts for the Amcor Mini Split Systems.\015\012201-266-8234 option 2\015\[email protected] ... AmcorAire UCHW-H12AF2 Split System Air Conditioner

My digital thermostat has shut off after a power failure. There is absolutley no display appearing. I pulled the thermostat off thinking maybe the batteries were no longer working but came to find out that the thermostat does not have batteries. I then went and bought a brand new thermostat that does have batteries for the display but when I properly installed the new one, the display worked (of course because of the batteries) but niether the heater nor the airconditioner comes on when I tried


Check inside the air handler for a small 3 Amp fuse or wire that may have come off of a terminal. ... Carrier 38CKC036 Air Conditioner

I am working on an older Williams gas wall heater. Pilot lights, heater comes on- after 1 hour cycles off, kills pilot light. one year ago installed new gas regtulator. DJWilson [email protected]


You have some limit switches located around the unit one high one or two around the middle one of them is opening and not closing. You need to take off the cover and locate the limits undo the wires and ohm them out you should have complete circuit ... Air Conditioners

My digital thermostat has shut off after a power failure. There is absolutley no display appearing. I pulled the thermostat off thinking maybe the batteries were no longer working but came to find out that the thermostat does not have batteries. I then went and bought a brand new thermostat that does have batteries for the display but when I properly installed the new one, the display worked (of course because of the batteries) but niether the heater nor the airconditioner comes on when I tried


What you have is a 24v control circuit problem. There is a transformer in the air handler ( inside unit ) you will have 220v on the one side and 24v on the other. If you have 24v from transform there is a small fuse on the pc board that could blow du ... Carrier 38CKC042 Air Conditioner

My Goodman Model CLQ60-1 14 SEER air conditioner makes a loud banging/grinding/screaching on start up within the 1st year of ownership. A start capacitor was installed but no change. Th sound is louder when it is hotter. The A/c repair company thinks that a new TXV would fix it but if not a new compressor. Do you have a fix?


Sounds more like the compressor. ... Goodman Air Conditioners

Air conditioner comes on fan only. the compressor doesnt seem to be coming on. the is no cool air blowing. the unit is brand new and was jusy installed.


There will be option in remote to on the fan and compressor separately may be you would not have on-ed the compressor through remote or else there would have been any loose connection in the wire which connects the compressor ... Friedrich Air Conditioners

Does not seem to be sufficient cool for a 1600 sq ft manufactured home coming from the Coleman unit installed. Some vents more air, others less air. Unit runs without stopping ever. Can you give us some help? Unit about 7 years old. John


Hi John, depending on the size, I would need the model number from the outdoor unit if it is a split system, you should have 400 cfm per ton of cooling. If you have a 1600 SQ' home, and a 3 ton unit, 3 x 400 cfm is 1200. It would be to small. There a ... Coleman Air Conditioners

I HAVE JUST HAD A v-lEC asw h18a4hsa aIR cONDITIONER INSTALLED. wE HAVE POWER GOING INTO IT, THERE IS POWER IN THE BOARD, BUT THEN THE POWER IS LOST SOMEWHERE AND IT WILL NOT WORK. tHERE IS NO FUSE ON THE BOARD THAT WE CAN REPLACE IF FAULTY. PLEASE HELP THIS IS A BRAND NEW AIR CONDITIONER.


Take it back and or demand a new one there is a law providing replacement or refund providing you have the receipt for it ....this is my only answer as you should already know this ...if defective they must replace or refund your money ...don't take ... Air Conditioners

I have a 5 year old RUDD heater. Burner turns on for 5 seconds then shuts off. Air filter was plugged. Replaced last week and thought prob was solved. Prob is back now. Tried pulling new filter out a little for "extra" air but no improvement.


Hello,Make sure the flame sensor is clean near the burners, The flame sensor is a metal rod that is on the opposite side of ... Air Conditioners

Brand new portable air con- burn smell


Two units, same plug, burning smell ... hire an electrician to check your wiring ... Sharp CV-P09FX Air Conditioner

Carrier 38CK036330 Hi,  I totally know nothing about air conditioning. It's getting so hot in LA and we really need help since our house has a 18-month old child. We have a Carrier 38CK036330 central unit, and it's not cooling the house as we'd like it to. It's already about 13 years old and we are looking for a new one to replace it. The question is we cannot find this model anymore, or do we have to replace it with the same model?? What model or brand would you suggest for a 1350 square feet h


The model numbers change.You have a 3 ton system.The make and model that you replace it with is not nearly as important as a quality install.Do your homework on picking a contractor that you can trust.Have them do a load calculation to make sure a 3t ... Carrier 38CKC060 Air Conditioner