I have a honeywell Design Air reverse cycle aircondton system. Two weeks back it stopped working. When I switch it on it starts the system. The air is flowing but it is not cooling. what could be wrong and how long normally it takes for a repairer to fix the problem. Just need approximate cost before I call them in for service.


Answers :

Hi, Just to to let you know, I am a contractor for heating and air conditioning. You have a split system heat pump it sounds like to me. If you have the indoor unit and an outdoor unit, this is a split. If the blower is running but not getting cold air, there could be several problems that would cause this. The service tech should be able to troubleshoot and find the problem in 1 hour or less. Depending on who you call, you are looking at anywhere from $65.00 to $85.00 per hour. Some places also charge you a travel or truck charge of $20.00, try and stay away from them. It will be a 1 hour minimum and in 1/4 hours there after. It could be a quick fix, breaker, fuse, or a serious problem as a compressor. This is what you are looking at. If you do have a split system and the outdoor unit is not on, check the breakers and fuses before you call any one. This may save you many $$$$$!! If you have a system that is all in one or a package unit and the blower comes on, make sure the outdoor fan is running ( condenser fan motor ) and listen to see if you can hear the compressor running. If you do have a split unit, go to the outdoor unit and see if the fan is running and compressor also. If not, check you're power supply. You may get lucky.
Sincerely,
Shastalaker7

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a honeywell Design Air reverse cycle aircondton system. Two weeks back it stopped working. When I switch it on it starts the system. The air is flowing but it is not cooling. what could be wrong and how long normally it takes for a repairer to fix the problem. Just need approximate cost before I call them in for service.


Hi, Just to to let you know, I am a contractor for heating and air conditioning. You have a split system heat pump it sounds like to me. If you have the indoor unit and an outdoor unit, this is a split. If the blower is running but not getting cold a ... Air Conditioners

I'm having a problem with my heating and air system, my heat only works on emergency heat ( and run 24/7) if i turn it to regular heat it only blows cold air. i dont think my outside unit fan is turning( i could be wrong about this one) how can i fix this problem so i dont have to run my emergency heat all the time


If your Heatpump's fan isn't running but your compressor is, your fan motor is out. If nothings happening at all ensure your getting power to heatpump (ex: breaker tripped, fuses blown on outside power switch, or fuses blown in breaker box?) ... Air Conditioners

Raypak pool/ spa heater Low NOx Model 407A: Will take long time to fire, stays in spark mode, and then when iit does fire, it shuts off and takes long time to fire again. If you can get it going it stays on until desired temperature is reached. Repair company gave up on fixing it after multiple trips and stated that the burners were dirty and needed to be cleaned. Have pulled out burner tray and cleaned everything off with wire brush. Put back together and have same problem. Interesting note it


The pilot is not proving to the control.Check that there is a GROUND/EARTH stake to the pool heater in the dirt.The pilot assembly needs a ground wire too the control. ... Air Conditioners

Air conditioner runs for a few hours and it works - it cools the house. Then it stops cooling - the fan still runs but it doesn't blow out cool air any more. It seems like it's overheating or something. It will blow out cool air if it has not been turned on in a while but once it's on too long it stops. I was told it could be the fan motor and the a/c guy changed the fan motor today but that didn't fix the problem. Now he says it might be the compressor or that I need a new system. I'm jus


The things I would check:\015\012Is the system properly charged with freon? Sytem may be overcharged.\015\012Is the compressor out on internal overload at the point of failure? If the overload isnt tripped and the compressor is having tro ... Air Conditioners

I live in Florida, my a/c system, I believe it is a Rheem, has been heating the house fine all of this winter no problem. With this last recent cold spell, I turned on the heat and all that is blowing from the vents is air that feels a few degrees warmer than the air in the house, it does very slowly start to raise the temperature in the house but is taking a very long time. I have stopped using the heat for fear of damaging the inside and outside units, need help


I would call someone that knows how to check the pressure in the outside unit. I would run emegency heat if it gets to cold. Switch the thermostat from heat to emergency. If the outside unit was running when the temperature was to cold and not going ... Ruud Central System Air Conditioner

Our floating air system from Friedrich is leaking a lot of water,how do i fix this problem,what should i look for when repairing the unit?


The drain hose could be clogged or the drain pan could be blocked. A\015\012service technician can correct this. Give an air con technician a call.\015\012This can be done by yourself if you know what you are doing but it is\015\012best to leave it u ... Friedrich M18CF Split System Air Conditioner

My hvac duct work on one of my central air units has a lot of condensation and causing puddles of water throughout my basement. Do you know what the problem is? The drain lines don't seem to have any leaks. There is condensation at the main supply unit of the HVAC system (gas forced air system). Can anyone help understand what the problem is and how to fix it?


Could be just not insulated enough is this a new instalation? the humidity is too high around the ducts is their a return air vant close by that you can open? you need to lower the humidity or seal the ducts so it cant get to them dan ... Air Conditioners

The fan for my air conditioner will not turn. When we cut the system on it makes a humming sound and the light go dim for just a moment and this goes on repeatedly. No heat or air. We have a dual system. One outside and the other is in the attic. Can you help. I am on a fixed income at this time and no money for a repair man.


If the humming noise is coming from the attic it would indicate that the blower motor on the air handler is trying to start but the rotor is locked.If the humming noise is coming from the outside unit and the fan runs but the compressor d ... Air Conditioners

My 3-year old LG air-conditioner was leaking water. So i called some 'experts' to come fix it. This is the first time I called for maintenance service on the air conditioner. The 'experts' dismantled some parts of the air-conditioner and washed out a lot of dirt and sticky stuff. After they put the air-conditioner back, there was no more water leaking but I noticed 2 new problems. When I switch on the air conditioner, the mouth does not immediately swing open, it takes about 3 minutes before it


White snow.. I had this issue when 2 inside unit electrical lines were hooked up backwards at the compressor. The compressor would pump too often and overcool the inside unit, because it was using the wrong temperature sensor. But you could have a ... LG LS-L1210CL Mini Split Air Conditioner

System pressure for puron read 280 and 135 for low side. System is not cooling at all. Suction line at air handler is not cold at all. System has had problems with leaks and customer has told me some techs have added refrigerant which I suspect has affected the mixture of the refrigerant. What should I do to bring thge system up to it normal capabilities. Also amps for compressor was 8 and is rated for 23 RLA


The system must be leak checked, refrigerant recovered, evacuated, a drier installed, and recharged to the correct subcooling, (I assume this is a carrier since you reference "puron")\015\012the low side pressure seems to be in line the high si ... Air Conditioners

I have a split system. One system does not cool or warm, but there is air coming out. The other system is functioning normally. Any ideas what the problem could be?


I would check to see if the compressor is running in the outdoor unit when the indoor unit is on.It needs the main power to be on and a signal from the inside unit that controls the relay.Could be something is miswired.\015\012Contact me for mo ... Air Conditioners

Ok..here's one. I have entire air duct system that is condensating ON THE OUTSIDE, UNDERNEATH. I noticed the problem before and after cleaning the coil in a closet air handler. Air runs fine, cools normal. But this condensation baffles me. It is even on the plenum! The pipes seem wrapped fine, and the plenum is good to go as well.


Not moving enough air or duct work is in a unconditioned space and needs to be insulate. what are your freon pressures, suction and liquid line temps, and indoor wetbulb ... Air Conditioners

We have a brivis evaporated cooling system P63. The unit was leaking water inside and when the plumber came out he couldn't find anything wrong with it then the Brivis technician came out and said there was nothing wrong but all of a sudden it stopped working after the Brivis technician fiddled with it but is saying that there was nothing wrong in the first place so it's not a warrantee problem. Do you think this could of just fixed it's self?


Is the unit still leaking?\015\012Is water coming out? \015\012If the unit is under warranty, it should be covered, shouldn't it?\015\012Is the unit working at all now?\015\012Please clarify and state the current condition. I ... Mastercool 67471 Evaporative Cooler Air Conditioner

Airflow We have a new ducted PEH-MYB reverse cycleairconditioner. We set the temperature at 20 degress for heating. Once it reaches it it then blows out cold air. We have had someone come 4 times already to fix various problems. It is not nice to sit near a duct and feel cold air. I thought the air flow was meant to stop, then start uo again when the temperature dropped just like our gas heaters? Am I wrong?


Go to www.mrslim.com. Look under the tab for library. Ib there you will find the troubleshooting guide for this model. Make sure the remote is set for cool and make sure the fan setting is not on automatic. ... Mitsubishi Mr. Slim MXZ30TN Air Conditioner

I recently purchased a used ac for my rv. it has two and one had gone out. the air coming out of the new one only gets down to 60 degrees while the air out of my old one is 50 degrees. they are both the same brand. does this mean the new one has something wrong with it or is it normal for some ac's to blow colder air i dont know is is should take it back or if it is working like it is suppose to help


No it means you 50 degree one is working better than perfect. Clean the one that is only getting down to 60 degrees but remember if a unit is dropping the air temp by 20 degrees its working fine. You ck this by cking the air at the intake where the f ... Dometic Rooftop RV Air Conditioner

We have a Vulcan ducted heating unit model HX100, recently we have experienced problems with the unit where is it not heating the house, the unit goes on but blowing cold air. We have had a couple of technicians to repair it and still not working. One fixed the switch pressure & the other the flame sensor connection. We have been advised that we may need a new unit or repair the board. As we have an illness in the family, we would like to know whether we need to purchase a new unit as p


\015\012We had the same problem with our carrier heater 4 year or so ago. We had a technician and electrician try to resolve the problem. What the tech suggest was to replace the main component ... Air Conditioners

Ceiling mounted system-AUY25RLD serial no P002712. Refrigerant R22 Outdoor unit AOY25RWDL When AC unit is switched on it throws cool air for a while then normal warm air and on the control panel it shows 2E:EE. Can you tell us what is wrong?


... Fujitsu Air Conditioners

A/C Model: FAC107P1A My unit is not putting out cold air. The temp wire is not touching the coils. I've cleaned the filter, and behind it. What do you think the problem is? What needs to be done to fix the problem? Could it need Freon? What type of Freon does it take? I have a certified person to put it in, but I have to get the Freon myself. Is it a sealed unit? Will it be obvious to him, where to put in the Freon? He said that he's not sure, but hasn't looked at my unit yet. I have to g


Hello, if the filter, evap, coil, condenser coil are clean then most likely the unit if low on freon. most window units take either r 134a or r -22, it will say on the data plate on the unit. To charge freon into the unit a piercing valve will need t ... Frigidaire FAC107P1A Wall/Window Air Conditioner

Hellos sir, I have haier 18-ax window AC, but I am facing display problem. all remote and display shows but while starting power light on the AC Display shows Stand by mode, Sleep Mode, Swing Light are on... And while using remote then Stand by mode off but sleep mode and swing mode and 1hour off light still on. Problem is that our AC not blowing air due to this reason. I think some switch are wrongly placed while playing with remote of AC. If you have some keys to repair AC with Remote.


... Haier Air Conditioners

I have a goodman spliit system clj42-1c. Outside fan does not run. I removed it and gave it power and it came on. Then with fan removed I powered up the unit the compressor hums for a minuite then cuts off but it never seemed that it was realy working. Thear is freon in the system. I need to know if the capasitor is at fault or if the compressor is bad. I am an air craft tech so I have a multimeter and enough know how to find the problem. I just dont want to purchase the wrong part. Can u tell m


If your multimeter has a Capacitance Meteryou can test the capacitor. There are ways to broadly test a ca ... Goodman CLQ36AR49 Air Conditioner

I am seeking further assistance per my recent air conditioner problem. See below. >Hello. The EE error indicates that the time >delay board {TDB} is faulty. IF you are >technically inclined you can go inside of your >unit and by pass the time delay board. This is >the quick fix and for the most part you will >won't miss it anyway. Other wise, at least now >when you call a repair shop you can get their >price upfront and shop around. > >IF you do want to fix it your self, here are >the step


Firstly the wires meant for low voltage side should be considerably thinner in comparison to the high voltage one and much stiffer too. If you can still power up, then those carrying higher voltage would make the tester glow by just holding the teste ... Air Conditioners

Boiler unit My problem is: I have recently renovated my house. In doing so i removed one of the raditors. I had to drain out the system to be able to take out the rad. Now i have to refill it... i am totally lost. what i do know is that i wll have to bleed out the air as the water rushes through to all the different rads.... what do i need to know about doing this.also how does the expansion tank come into play I am seeking answers on how safely refill my system so i can once again have heat. th


In a hydronic system for heating you must insure that the pressure on the boiler is maintained during the process of bleeding off the air from the system. There is a regulator for the water make-up to the system which normally maintains 12 PSI with t ... Air Conditioners

I have a Lennox heating and air system. It's 5 years old. The tape that hold those long tube things together has failed and the tubes are disconnected from the vents that blow air into the house. I have used duct tape as a temporary fix. I'm told that when winter comes that my duct tape will come apart. Where can I buy the right tape to put everything back together? I have tried to get contractors to do the work, but so far they are all booked up for weeks. My electric bill is sky high probably


Sounds like a lousy job. Best tape is alluminum. You can pick it up at Home Depot or Lowes. If the tubes are flex duct be sure to pull back the outer insulation and tape just the inner lining ... Air Conditioners

I have 3 goodman system but my goodman ckl30-1g, stop blowing cold air a few days ago. the inside unit attempts to start and the outside compressor fan runs just fine but no cold air is being pushed through. I normally troubleshoot my my problems but this one has me puzzled. Does it have anything to do with the "warning" of overflow shut off device? where is this located?


The fan may be running on the condensor, but; Goodmans usually come with a dual capacitor. A lot of times these fail and the compressor cuts off on the overload. Turn off the power and check for a bulging capacitor. It can still be blown even if it i ... Goodman CKL30AR30 Air Conditioner

The heater is not working on our fujitsu AOT24U split system. The tray under the outdoor unit(installed inside factory above office) appears to have a gold/yellow oil in it.Is it oil from the compressor or refrigerent? Either way it doesnt look promissing! Can anyone shed some light on this problem and let me know what it will take to fix or if it can be fixed! Cheers Cold


... Fujitsu Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.1439 seconds