Having problems with your Air Conditioners ?

Ductless split system, single zone, gives trouble display. Operation light flashes 6 times rapidly, then both Operation and Timer lights flash 5 times at 1 second intervals, then the timer flashes 1 time at 1 second interval. What do we do? The unit doesn't put out heat. I only feel air when I click the Coil Dry Button, but the Trouble Display continues. Unit will not shut down. I flipped the main switch, connected to the heat pump, on the exterior of the house, but it started back u


Answers :

What make and model is it?

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Ductless split system, single zone, gives trouble display. Operation light flashes 6 times rapidly, then both Operation and Timer lights flash 5 times at 1 second intervals, then the timer flashes 1 time at 1 second interval. What do we do? The unit doesn't put out heat. I only feel air when I click the Coil Dry Button, but the Trouble Display continues. Unit will not shut down. I flipped the main switch, connected to the heat pump, on the exterior of the house, but it started back u


What make and model is it? ... Air Conditioners

Futitsu Inverter Air-con {ASTA09LCC}- Fan operates but no refridgerated air. Remote is on 'cool', fan speed is on medium. When the unit is switched on the Operation light (red) and Timer Light (green) flash twice together, then Operation light flashes five times this reapeated after about five seconds. I am told that this can help diagnose the problem. I have reset the remote to cler any chance of the 'Timer' being set.


To cancel the timer, press timer on setting until it comes 00.00. Or remove batteries from remote and re fix after few minutes. If still problem persists, check and rectify error code of e-5 as follows: Comms Error, check your wiring, rem ... Fujitsu 24C1 Air Conditioner

Power went off for approx 3 seconds, air con was on at the time, now the front panel of lights, eg: swing, operation, timer buttons are flashing and it is not responding to remote. We have turned off in power box and back on. As soon as the power button on remote is pressed, same lights flashing and no operation. Sorry we don't have a manual for it, any ideas would be greatly appreciated.


Hi. the control panel board has failed. it will have to be repaired or replaced. ... Air Conditioners

Fujitsu inverter hello my name is jim. my fujitsu works on all areas except heating. when turned on the it makes all the moves as it is about to work but stops as it is frozen with very little air coming out.it also has the timer light flashig constently and the operation light flashes 5 times every 10 seconds. on cooling , dry , fan it seems to power on and all levels of speed work ok.


... Air Conditioners

Fujitsu ASU9RLQ I have a new mini split heat pump/air conditoiner installed. The electronic air cleaner does not operate correctly. After 4-5 minutes of operation, the Operation (red) light on the front of the wall unit flashes 4 times and the Timer (grn) light flashes 7 times indicating an air cleaner monitor trial protection error. The filter is clean (new) and the front panel is closed. I'd appreciate advice re how to resolve the error.


Check indoor unit sirkit board ... Fujitsu 18C1 Air Conditioner

Red light in blower compartment flashes 9 times, this is a 2000 amana model 80SSEIIQ MODEL NUMBER GUIV090CX50. it flashes 9 times then the light stayes dim for 2 or 3 seconds then light ups and begins flashing 9 times and has been doing this repeatly for weeks. the air conditioner works fine. and this is a heating related problem if I'm correct.


... Amana Air Conditioners

THE RED (OPERATION) LIGHT AND GREEN (TIMER) LIGHT ON MY FUJITSU DUCTLESS AIR CONDITIONER ARE FLASHING. PRESSING THE START/STOP BUTTON ON THE REMOTE CONTROL DOES NOT MAKE IT WORK. SWITCHING THE BREAKER OFF AND ON SOMETIMES MAKES IT START BUT NOT ALWAYS. AFTER IT STARTS IT CAN STOP SUDDENLY, AND THE RED AND GREEN LIGHTS START FLASHING AGAIN. THE RED LIGHT FLASHES 6 TIMES, THEN PAUSES, BEFORE FLASHING 6 TIMES, WHILE THE GREEN LIGHT FLASHES CONTINUOUSLY. INDOOR UNITS MODEL #ASU12D1. OUTDOOR


... Fujitsu Air Conditioners

My panasonic air conditioner system keeps turning itself off and the timer light comes on flashing. The remote hasn't had the timer set. I have tried reseting the unit via the remote controll however it comes on for a split second and then turns back off again with the timer light flashing again. Can you please help?


... Air Conditioners

My fujitsu asta12lcc timer light flashes 3 times then stops for 3 seconds then flashes again 3 times ect,and it dosnt heat


... Fujitsu Air Conditioners

I have an Alpha CB28 combination boiler and it is not working at all. The bottom neon indicator light is flashing every second and the helpline suggests it is a temperature sensor fault. I have had it replaced and it still does not work. It did work for a short time last night when the new part was fitted but today it has not worked. The boiler appears to fire up for a few seconds and then it clicks off again, so the light is only staying on for a short time.


Try tapping the 3 relays on the pcb,"thats the circuit board under the front cover...\015\012it sounds like a dodgy relay thats starts up the pressure fan in next to the flue....\015\012maybe a dry solder joint,maybe a new relay needed... ... Air Conditioners

We have a slim heater/ air conditioner on our wall. It's been in airconditioning mode for the summer. I'm having trouble 1 . it shuts off within seconds of turning it on. I've tried to cancle the timer. Lost the manual. 2. I cant get the fan to blow warm air, the blade to even rotate but it works with cold air!!!ouff... ....the remote is on heat ....temp says 74 on both wall and remote mdl # LMN120HE suggestions?!? We're cold.....


This is a tippical heatpump problem. get the revers valve unstuck. energise the coil to the valve, on and off. make sure the power is on to the coil.(HEATING MODE AT FULL TEMP). if you are not electrical minded leave it be. get someone with electrica ... Mitsubishi Mr. Slim MXZ30TN Air Conditioner

Sharp AY-A249J Split System Air Conditioner not working, the timer light flashes 5 times and the power light does not flash at all, the remote has limited function, it turns the indoor unit on and off and the louvre opens and closes, the Outdoor unit AE-A249J does not turn it, it does have power as the PCB has a red light on, not flashing just a solid res light is on


Thanks for your replies, I had a Sharp authorised tech look at it and im told it's the indoor circuit board. Im told its a $360 repair job all up, that sure beats replacing the entire ac or putting up with the heat... ... Sharp AF-S120FX Air Conditioner

I have 4 header split type air conditioner. Time & again it stops and operation and timer light flash altenately and I have to to turn off the power at the switchboard and turn on again to reset. Sometimes this happens 2 or 3 times a day and other times it operates correctly for days. I have cleaned the filters and checked the electrical connections. 2 years ago I had a tech from Fujitsu who came and checked everything and could not find any faults. I am getting a bit concerned as this is occur


Hi,\015\012On the days it happens alot is there a temperature corolation??? Are these days warmer or colder then the days it runs all of the time???\015\012\015\012Have you checked the charge on the unit???\015\012Would there ... Fujitsu Air Conditioners

I have a fujitsu inverter air conditioner. when i turn it on the power indicator flashes twice then the power indicator and timer flash 6 times then there's a slight pause before it repeats itself. Any ideas? We are freezing!


... Fujitsu 18C1 Air Conditioner

Fujitsu air conditioner has a constant timer light flashing and an operation light that flashes 5 times and repeats. i have a AWU36CX INDOOR UNIT


... Fujitsu AOU36CLX1 HALCYON Outdoor Mini Split Cooling Only AC - 36,000 BTU

System starts but does not seem to cool i.e.fan and outdoor unit operate then stops after approx 10 minutes. Yellow (timer) lamp flashes twice then red (operation) lamp and yellow lamp flash together 3 times then approx 3 second gap till code repeated.


Hi,\015\012The unit is low on freon...\015\012The unit will run for the 10 minute time because it over rides the low pressure switch for the ten minute period or the low temperature sensor is over riden for the ten minute period then it l ... Air Conditioners

No cool air... red operation light flashes 5 times, green timer light flashing continuously. Model # AST9LSBCW Please help it's hot here in Perth :(


... Fujitsu 18C1 Air Conditioner

Hi, I have a split system air con model ASTA12JCC installed at home and haven't used it for a while and last night it wasn't working and come up with an error code. The red operation light flasted eight times while the green timer light flashes 4 times. Do you know what type of error i have ?


O4ID Pipe Sensor/temp sensor Open. Check and replace it. ... Fujitsu 18C1 Air Conditioner

No A/C My unit will power on and the fan works, however when I turn it to the Cool mode I can hear a click in the unit, the cool light comes on for 5 seconds or less, then it will click again and the light will flash 9 times. The warranty on the unit is 4 years however only covers parts, labor is $90 per hour......Is it just a fuseable link/circuit breaker?


It seems that that the overload of compressor is tripping on and off, either your compressor overload is defective or the compressor itself ... Danby DPAC8399 Air Conditioner

I have split dual zone art cool air conditioners. Both worked this morning when I turned them on for the first time this season. I came home from work and nothing. I checked power sources and reset remotes. On both art cool screens is the temperature and "ch" flashing back and forth. The remote will turn it on for a split second and then turns off and goes back to flashing. Help! Thanks Bianca Zick


... LG Air Conditioners

Power failure and when came back on the green light is flashing and wont start we are in Katherine NT and power went off for about two hours, the air con was on at the time, the model is a FTKD718VMA, it has a remote, and as far as I can see the timer is not on. It responds to change of temp and all the other functions but will not get past the flashing green light.


Go to their website and there are service manuals that tell what is wrong using different displays on remote I tried to paste it here but it didn't work ... Cfm Daikin R410a Split System Air Conditioner

My Fujistu AST9LSACW split system air-conditioner wont blow cool air. the outside unit AOT9LSAC doesnt seem to be working at all. The power light stays on but the timer light flashed about 15-20 times a minute. please help...


There are two things you can check outside before calling a service technician. The first is the breaker to the outside unit. There is a breaker or disconnect near the unit. If there is nothing wrong with the electrical supply, check the refrigera ... Fujitsu Air Conditioners

I have a Rheem (Criterion) unit and i'am having promblems with the main burner staying on. When i turn the unit on everything operates like it should up to the main burner staying on.Once the main flame kicks in it will stay on for five second and the flame will go out along with the draft moter( for about three second the trouble shooting light will flash four times) then the unit will start cycling all over again from draft moter purging, glow plug will operate like it suppose to up to the mai


Run a wire from the sensor down to the control board conector. Bypass the sensor wire around the connector in the blower deck.\015\012The connection can be wire nutted on the sensor lead with the wire (16 or 18 guage stranded wire works) route ... Air Conditioners

Friedrich MW18Y3F I want to cool my house and there is no cool air comming out. My "operation" LED (red) and my "timer" LED (green) flashes together twice and the "operation" LED continue flashing 5 times. I don't know what happens.....one day everything works great, the other the cooling doesn't work...


... Air Conditioners

Fujitsu 12r2 operation timer both flash 5 times and time flashers 1 time


... Fujitsu 12R2 12,000 BTU Wall Mounted Single Zone Heat Pump/AC 14.3 SEER

A detailed question is important to get you a relevant answers