Having problems with your Air Conditioners ?

I had two very different quotes for installation. They recommended different models and different blowers. 15k vs 17k mxz4a36na vs mxz3a30 model. By getting the less expensive model and smaller blower am I going to be with less power and/or higher electric bill to run?


Answers :

The last two numbers in the model number indicates the Btu ratings. The mxz4a36 indicates that this unit is capable of putting out 36,000 Btus and only 30,000 Btus on the other. I would be concerned that the second unit is large enough to satisfy your cooling load. Forget the power, make sure the unit is sized properly.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I had two very different quotes for installation. They recommended different models and different blowers. 15k vs 17k mxz4a36na vs mxz3a30 model. By getting the less expensive model and smaller blower am I going to be with less power and/or higher electric bill to run?


The last two numbers in the model number indicates the Btu ratings. The mxz4a36 indicates that this unit is capable of putting out 36,000 Btus and only 30,000 Btus on the other. I would be concerned that the second unit is l ... Mitsubishi Mr. Slim MXZ30TN Air Conditioner

On the 22nd Sept.2010 I received my replacement remote for Model RAS-09CHA1R/RAC-09CHA1 A/C The price with GST & PP was almost $200.This is the only Hitachi A/C I have. My other A/C remote cost about $39 for a different A/C manufacturer. I find this extremely expensive and 1/3 of the cost of the Hitachi A/C.If the replacement costs are going to be this expensive I would be most reluctant to ever purchase another Hitachi product. Would you please explain the reason for this exorbitant price.


... Hitachi RAS-09UH Air Conditioner

With unit set to air conditioning, the controller board will not turn on the blower motor and the cooling coil freezes up. McNutt tells me the controller board is kaput and they want $550 for it. In the meantime they have jumpered over the controller so the blower runs constantly. Was hoping someone might be able to tell me where to get it for less. It is HSCI Furnace Controller For Use With All Gasses 1012-940, model HK42FZ011


? need more info like make model and serial numbers ... Air Conditioners

Hello, I have a Amana Air Command 80 model #GHI90A50, 22 years old. This furnace is on its third ingnition module (last one two yeras ago). The symptom I am trying to diagnose has been ongioing since this latest ignition module was installed. The furnace is short cycling, meaning it runs often once every 8minutes but for less than 3 minutes at a time. The sequence is as follows: Cycle start (small blower turns on), followed by the ignition module illuminating (yellow) for 3 seconds then turns g


If your furnace lights and the gas stays on for 8 to 10 seconds, then shuts \012right back off, then you need to clean your flame sensor with light sand paper \012or steel wool. You might need a new flame sensor, but most of the time th ... Air Conditioners

New Hampton Bay Model 640-657 Classic Collection Burgess 54" Celing Fan with Remote. I have had installed by electrician ,also re checked by different electrician. Both have charged me and told me it is wired correctly. Comes on some time by itsself and then light will not go out. I have replaced the battery 3 times with no help. I have wired into a wall switch . prior to the Fan. Could use some help. Is there a kit I can wire without the Remote. Fan is less than 3 weeks old. Getty costly to k


... Air Conditioners

Short Cycle I have an Intertherm Model 497580 in a manufactured home. It continually short cycles. The blower will cut on and cut off about every 2 mins. I have had two different "professional" HVAC people come out and it still does the same thing. One replaced what I think was a relay. Small round black disk with two wired. That was $138.00. The other came (twice) and check Tstat adjusted something on it. That was $50.00. It does seem to run longer if the grate and filters are off and


It sounds to me like the motor itself is going off on its overload protection. taking the panels off may be allowing it to stay cool a little longer. also it sounds like the first guy replaced some type of temp. sensor. ... Intertherm P3RA-048K Air Conditioner

Model TWEO36C140A1 blower will come on if I throw the breaker switch...but thermostat doesn't seem to be in sync. Fan will run in "on" position and once blower is running, in auto. Blower ran for quite awhile, a couple of days, until I touched thermostat as we were roasting. I knew that would be a mistake! This morning, blower won't run when I switch breaker back on even after letting the motor cool for several hours. Is there a relay switch somewhere? I don't see it. Or does thi


... Air Conditioners

I have an old RUUD central AC unit that started blowing hot air. I set the thermostat to off and set the temp gage higher than air temp to turn the unit off and save money, but inside blower unit runs constantly. I'm trying to save money to have it serviced, but noticed my electric bill was higher that last month when the ac was working. The bill was about 4 times higher than the winter when ac is off and the gas heat kicks in. Can the blower running constantly cause this power usage and what is


HelloOkay did you check your thermostat to see if you have the fan switch on auto? The switch must be on auto or the fan will continue to run. If the thermostat fan switch is on auto then there is a malfunction in the thermostat probably ... Air Conditioners

Just installed new Goodman 95% updraft furnace with 3" supply and vent lines going out through wall. Gas valve won't open. Circulation blower runs in manual on, A/C system runs fine. I have used an ohmmeter and voltmeter to do checks. The entire series of safety switches are closed. When the small blower is running, both pressure switches close. The igniter comes on but there is no voltage to the gas valve. Just after the igniter goes off, I hear a relay click, the circulation blower seems


Make sure you have bled your gas lines. If any air is in the lines, it will cause the unit to do exactly what yours is doing. The relay "click" you hear is the gas valve opening, but if there is no gas, it will not ignite. This is common for a new in ... Goodman Air Conditioners

My 8 yr old Amana heat pump, model RHE48A2D with Honeywell progammable thermostat in heat mode has the blower running constantly. When there is a 6 to 8 degree differnce between room temp and thermostat setting compressor runs as it should, the closer it gets to thermostat setting, it will run about 30 seconds, blower continues to run until getting just cool air, about 5 minutes, compressor kicks back on for 30 sec., continues to do this, thermostat shows it has reached set temperature,


Hi, It sounds to me like what you are describing is, that when it is 6 to 8 or so degree difference then the stat says, unit operates as it is supposed to but then before it satisfies the t-stat, it shuts the compressor down long enough to start cool ... Air Conditioners

I have bard central unit model# a/c ph11361 blower not running


If your unit is a gas unit, then its 115v and if its and electric unit 220v. If you are getting voltage to the motor, 115 to ground but the motor isn't starting then the motor is bad. The black wire is high speed, red is med., blue and or yellow is ... Air Conditioners

Hi, I have Lennox gas furnace Model G12Q3E-82 (about 30 yrs. old). When running the A/C, I noticed there was water leaking or dampness around the bottom of the furnace. I removed the hose from the drain spout on the evaporator and noticed it was plugged and unplugged it to drain some water out of it. I also removed some water that accumulated in the bottom of the frame that wraps around the blower motor and fan wheel. I have a problem where now the blower motor runs for about 1 to 2 minutes then


Hi Todd, you did the right thing by checking the uf on the run capacitor and it is with in range , the reading is good. What is happening is with the condensation building in the pan, the blower motor has picked up some water and burned the windings. ... Air Conditioners

Intertherm Electric Furnace in mobile home Model# MRAC 2317 SN - 79JE0501 Question: The blower stays running all the time. I have to turn the main breaker off to turn the blower off. The unit is heating when it is running. I have replaced the thermostat about 3 years ago in the summer when I had a AC problem. Would the fan switch on the furnace possibly be the problem? It has an auto & on position on the switch. It clicks when you switch to the on position but does not click when you put i


... Intertherm Air Conditioners

My Ruud furnace blower motor runs and gas is ignited but after 3 seconds the burners go out. The blower still runs and it keeps trying to ignite and then goes out every minute or so.


Sounds like a dirty flame sensor, on thenopposite side of the igniter there will be a metal rod, clean this rod with steel wool ... Ruud Gas Furnace - Excellent Condition - $350 Obo

In ac cycle blower will run for about ten min then go into lockout condenser will still run if cut power for 30 secs it comes back on. (Newer blower)


Maybe your main power board or a fan motor/capicator ... Goodman Air Conditioners

My compressor unit outside runs and cools Freon but the inside blower has a problem running. the model # is 2TEE3F31A1000AA. The fan control, in fan run control mode, shows a bright green for the fan LED and the CFM selection LED varies with the rotational speed of the fan. The motor tries to start showing , initially, a jerky back & forth movement. It squeaks some and may, or may not, start rotating. If it starts the CFM LED goes bright/on no flicker and the motor runs briefly (5 seconds) then


Hi, from what you have told me, you are loosing the bearings in this blower motor along with windings. This motor is rubbing the blower housing, tight when you turn it, and when it jerks when it tries to start tells me that you have burned or very we ... Air Conditioners

Have six year old Bryant electric furnace with heat pump, no gas. Old blower motor was going out and replaced with another generic blower motor. Wired the new just like the old and changed capacitor. There are some differences between old and new. Old says "Volts 208-230" and new says "Volts 115." Problem is blower turns on and of, over and over again. Help?!?


Hi,\015\012You totally have the wrong motor....you need to get a 208-230 motoro on there for it to work... in fact you probably already have ruined the 115volt motor...the voltage for that motor is to be 115v and you are probably running 130 vo ... Air Conditioners

I have a Arcoaire Gas Furnace (Model# GNJ100N12A1), that will not fire up. It has a White Rogers Digital Stat. First the Stat seems to be faulty, since it reads 70plus in a house that has a temp of 30 or below. I can adjust the Stat and the blower motor will run. The rollouts (3) were reset; the inducer fan would run; then the unit would cycle and shut off. Now the inducer won't run. The ignitor is good, but would never glow. A friend tested the current coming from the Stat, and found 24


Sounds like a faulty board. shut the power to the furnace off for a minute then turn it back on. Make a call for heat at the thermostat. The inducer should start and close contacts on a pressure switch . Once pressure switch closes the hot surface ig ... Air Conditioners

I have a dometic heat pump a/c basement park model unit. The fan is not working. The compressor runs, but no air inside or out. I have power into the run cap. but not on the brown wire to the fan from the run cap. I also have no power to the fan high or low off of the relay board. Where do I go next to isolate?


... Dometic Air Conditioners

I have a Goodman Model number AR24-1 unit and the blower moter will not start with it turned on to fan or cool or heat. I have checked the thermostat and the unit runs outside. Just no blower. Can I jump the blower motor as I replaced the capacitor today. Hear are some numbers that may help. Part Number #15212-50 Volt 208/240 Amp 1.5 HP 1/5 No heat Kit It has a Goodman switch board # B1370735 that I can check with my meter if needed. I have checked the thermostat in the attic also. Seems like


... Air Conditioners

I have a Ducane fits all 92 my lanlord installed,about 3 months ago.The thermostat is a new digital. The temp is set on 68,and if i go to 72 for example,the furnace starts and runs fine for about 3 to 5 minutes.The burner shuts off,the blower continues to run,And the buner tries to relight,and it fails to do so.The only way to get the furnace to run again and blow hot air is to shut the system off and restart.


Sounds like you are not proving flame to me. Could be a variety of things. I think it may be the board...but that is a guess from past history with Ducane ... Air Conditioners

I have a goodman ar24-1 blower motor that will not start. I have changed the capacitor, checked the thermostat, spun the blower motor but still will not start. Outside unit runs but no blower. Any ideas? This is a central air unit that is less than 6 years old.


Check the relay or sequencer that controls the blower if it has one of those. If the fan is controlled by a circuit board then you problem may be there. If it is controlled by a circuit board then you can check for power at the fan connection when th ... Goodman CKL24AR24 Air Conditioner

The model number as listed on the receipt is CKQ24. The Blower moter in the air-handler is not running. When the fan-only switch is turned on, the blower motor will attempt to spin by pulsing for about 2 seconds. It will repeat the pulsing cycle in about 2 second intervals. There is no smell of burning. When the unit is set to AC and auto, the evaparator coils do chill. The blower motor is a variable speed motor with an external ECM. How do I test the ECM and/or motor? What should I look for in


Personally I would get an exact replacement capacitor same voltage rating and microfarud rating. The capacitor will read something like 370v 5uf. I would be surprised if that's not the whole problem. If not it needs an exact evaporative fan replaceme ... Goodman CKL24AR24 Air Conditioner

I have this model of air conditioner and it shuts off from time to time. It will run for a while and then power down. Then when you try to restart it will run for a few mins and shut down again. But I tried it in a different out let and it will run for a longer period of time. It is not tripping the breaker on any outlets. Is this an issue with the compressor getting over work and it shutting down to cool off?


... LG LB1200ER Air Conditioner

Carrier Weathermaker SX model 58SX060-CC Blower runs all the time


Remove all power from the furnace, it is likely the brain in the furnace is need of being reset, from the battery replacement, why did you change the battery, was there an indicator telling you to change it?Many times just removing all t ... Carrier XHB123D X/Y Series Heat/Cool Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific