Having problems with your Air Conditioners ?

The fan speed in my mini split a/c indoor unit is abnormaly low even when set in High speed mode. This unit also has a powerful mode to raise the speed beyond High for 15 minutes, but it is not working either. I replaced the fan motor, the power supply board and the main board to no avail. Any help will be appreciated.


Answers :

Please change the fan capacitor,all will be ok afterwards.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

The fan speed in my mini split a/c indoor unit is abnormaly low even when set in High speed mode. This unit also has a powerful mode to raise the speed beyond High for 15 minutes, but it is not working either. I replaced the fan motor, the power supply board and the main board to no avail. Any help will be appreciated.


Please change the fan capacitor,all will be ok afterwards. ... Air Conditioners

I have 2 dometic roof top units on a 2002 MH that I recently purchased. 1 of the units only runs on high speed, the stat has a high low switch, the unit cools fine. The second unit, the comp starts, but the fan only hums, the shaft turns fine. I switched the start relay from the other unit, same result. I suspect that the start winding is open, but haven't checked yet. I am not opposed to replacing the unit because of age, condition of roof cover,and suspected cost of parts. Would appreciate any


Hi, unit # 2 sounds as though the run capacitor may be open, shorted, ect.When you say you changed relay, I assume you were talking about the capacitor. If the motor didn't run when you changed it, you do have a bad winding, or open as it just hums. ... Dometic Air Conditioners

I have a Sanyo khs1271 that is about three years old. For the last six months it has been making a high pitch chirping sound in both heating and cooling modes. I suspect the problem is the fan on the indoor unit as the chirping only occurs when the fan speed is on high. So far, the only solution to the problem has been to turn it on quiet mode, which reduces the fan speed and thus makes the unit's ability to heat or cool less effective. Does anyone know how to access the fan on the indoor unit


Hi You can try to check this link it has the user manual.Thankshttp://www.sanyohvac.com/assets/documents/user/Use ... Sanyo Air Conditioners

My bonaire evaporative cooler cycles from high to low fan speeds when set in the cool mode. It works fine at the required speed setting when just the fan (no water) is selected. It also dumps water immediatly the cooling cycle is turned off rather than holding it for about 40Min as it should. Sounds like a controller problem, but I'm not sure if it would be the touch pad or the board up on the roof mounted unit.


... Air Conditioners

My house had a power surge and now my inside fan will not come on. It is a frigidaire heat pump 3 years old. Model # b5bm-t49k-c 4 ton unit. Outside unit is ok. i replaced the circuit board but still have the same problem. It is a 13 cer unit? i have 220 volts at the motor but unsre how to verify if it is bad. Any ideas would be appreciated


... Air Conditioners

MY GOODMAN CPKJ24-1A UNIT WENT DOWN.TOOK FAN OUT SAW WIRES SHORTED OUT AND MELTED COMING OUT OF FAN MOTOR I REPLACED THE FAN MOTOR .THEN REPLACED DUAL RUN CAPACITOR THEN THE SWITHING CONTROL. TRIED TO START UNIT FAN RUNS AT A VERY VERY LOW SPEED AND SORT OF WISTLES WHEN RUNNING ALSO UNIT IS NOT KICKING OVER EVEN HAD CAPACITOR CHECKED WHY WONT MY AC UNIT COME ON


... Goodman Air Conditioners

Jusrt bought a mobil home with an Interherm unit. I live in Louisiana. When the air was hooked up is didn't cool very well. The fan motor outside had to be replaced. I was told it was the wrong motor and wrong fan blade It was replaced yesterday. When the unit was cut on it ran from 12;00 noon until 9;30 that night. The trailer just isn't cool. The ends of the trailer are fairly cool the but living room isn't so the unit doesn't shut off. Any help would be appreciated. Thanks


There are a few things you can try.Close the vents half way in rooms your not using often too force more air to where you want it.Inside coil and filter may be clogged or dirty.Change filter and clean coil with a degreaser spray,simple gr ... Intertherm P3RA-024K Air Conditioner

On a goodman model number aruf030-0100a-1a when the unit is off the fan motor will run at about haft speed i replace the board with relay on it but having same problem what i need to do now thanks


Try change the fan sequenser. ... Air Conditioners

I have a Goodman CKJ60-1c. A technician just replaced the cap due to the breaker tripping (he said cap was causing high amps). Once cap was replaced, now fan is running backwards. i checked wiring - everything seems wired according to schematic (no assist start installed). He says fan motor is bad and needs replaced. Never heard of a motor running backwards - aside from a wiring issue. Not sure if cap he installed is proper for unit. Cap is MARS 80 5 uf+-6% 440vac, 12297. Any advice?


... Goodman Air Conditioners

Air Cools well but after about an hour, water starts coming into the coach through the discharge air side. Unit does not freeze up but if I shut the unit off, the tray that holds the water drains quickly, but doesn't drain well when the A/C is running. I always run it at high speed initially, though when you put the AC on Auto fan, it starts at high speed anyhow. This unit is in a Newmar Mountainaire 40' diesel pusher motor home


Your evaporator is probably dirty and is blocking some of the air flow so the air has to move around the coil and starts coming in through the condensate drain holes. That stops the condensation (water) from draining out the holes because the air is ... Dometic Rooftop RV Air Conditioner

I have an intertherm central air unit in my mobile home that does not change fan speed when I click the fan speed switch. I've checked the fan relay which is good and energized in the ac mode which should put the speed switch in the circuit. It is a PSC fan motor and I haven't checked the capacitor.


You may ahve a bad switch but sometimes when they are worked on the servicrman bypasses the switch. Fan speeds are color coded black high blue med yellow med high and red low. Just for your info. Russ ... Air Conditioners

HVAC problem We have a bryant indoor hvac unit. The inside fan motor comes on in heat mode, but not in ac mode or in the 'on' position. The thermostat, fan relay and motor have been replaced. Can u help?


One thing you can check is the condensation line to see if there are wires going to it. This is the plastic pipe coming out of the indoor unit. If there is a float switch and the condesate line is clogged then it will not allow the a/c to operate. If ... Mitsubishi Mr. Slim MXZ30TN Air Conditioner

I have a Goodman Package unit Model # PGJ 03075-1. The blower motor only rocks back and forth while the compressor and fan run and begin to form frost on the pipes. I replaced the large capacitor, main control board, fan control board, thermostat, and removed the control module off the back of the ECM motor to look for burned areas. There are no visible burned areas. Any ideas on what to check next? Rick


The blower motor only rocks back and forth ? That means it is getting power. Most of these have their own smaller capacitor did you check it?\015\012Any sloppy vertical movement means the motor bearings are shot, the motor is what we ca ... Goodman CPLE24-1 Air Conditioner

I have a Coleman Presidential 7670 furnace in a mobile home. customer said it came on a couple of times by itself. I ran new wire, fan won,t shut off. Replaced fan switch, fan still won't shut off. Replaced t-stat, same problem. This is an older unit and has no board it has a fan switch a low limit switch, i,m guessing the other is a high limit and a fan relay. I have no schematic and am very frustrated can anyone help me please. Thanks. Brian from california


Brian, it sounds as if possibly the fan relay is stuck however, if the fan will not shut off I would suggest the following, Follow the wires from the fan to the relay on the relay disconnect the fan wire there and see if the fan shuts down if so t ... Air Conditioners

Lg Neo plasma inverter split model s18ahn isn't heating or cooling properly. When in heating mode air con will go into defrost/preheat mode for 5 minutes and then air con will blow out air for 5 seconds and then go back into defrost/preheat mode. When in cooling mode indoor fan will pump out air but will not get cold. In both heating and cooling modes the outdoor unit will not start up and the outdoor fan will not spin. I have just replaced the main pcb board and that hasnt made a difference. Bo


... Air Conditioners

A mate has a fujitsu ast24rba-w, the outdoor unit runs but the indoor fan won't go. Found indoor board buggered so I replaced it, fan still no go. Got hold of a fan that I know works and still won't run!! Checked the start capacitor and that meters ok. It won't even run on fan only. From what I can see the fan should run, there is nothing left to replace. Any advice would be greatly appreciated!!!


... Fujitsu 24C1 Air Conditioner

My compressor unit outside runs and cools Freon but the inside blower has a problem running. the model # is 2TEE3F31A1000AA. The fan control, in fan run control mode, shows a bright green for the fan LED and the CFM selection LED varies with the rotational speed of the fan. The motor tries to start showing , initially, a jerky back & forth movement. It squeaks some and may, or may not, start rotating. If it starts the CFM LED goes bright/on no flicker and the motor runs briefly (5 seconds) then


Hi, from what you have told me, you are loosing the bearings in this blower motor along with windings. This motor is rubbing the blower housing, tight when you turn it, and when it jerks when it tries to start tells me that you have burned or very we ... Air Conditioners

WHEN UNIT CALLS FOR BLOWER TO COME ON, YOU CAN HEAR BLOWER MOTOR RELAY CLICK LOUDLY ON BOARD BUT DOES NOT COME ON...... CHECK LEADS COMING OFF BOARD TO BLWR MOTOR AND WAS GETTING NO POWER..... IM THINKING THE BOARD IS BAD( OR RELAY ON BOARD) AND THIS IS HAPPENING IN COOL, HEAT, AND FAN ONLY MODE


I believe that you are exactly right. If you would like to know the part number and cost of the board, just give me the brand of the unit and the model number. I will find the cheapest place to get the board. ... Air Conditioners

This is a Fujitsu floor mounted aircon unit. In either heating or cooling modes the 20amp circuit drops out almost immediately after the soft start switch activates. The on board 5 amp fuse is not blown. The fan inside this unit runs very briefly before the breaker lets go. The wall unit fan is unaffected if used by itself.


Hi,\015\012You did not list a model number...so I am just speculating a bit here...\015\012It would seem as though the compressor is either locked rotor or the compressor motor is shorted...\015\012When the power goes to the compres ... Air Conditioners

I have a sunbeam 12000 btu window unit air conditioner. I can't seem to change the fan speed when it is in cool mode. When I put it on fan only it blows extremely cold air and i can change the fan speed. When i press the power button it stops blowing but it sounds like the motor is still running and I must unplug it to get it to stop.


Sounds like the switch is wired wrong.\015\012When you put the switch on fan only the compressor should not run at all, therefore their shouldn't be any cold air.\015\012Check the switch to see if it's wired right. ... GE Profile ASM10AA Air Conditioner

Our evaporative cooler fan does not start when we turn on our unit - it will run if I get up on the roof and start the fan blades spinning... We could smell a burnt motor smell when the problem started. Is it just a fuse? or is it a new fan motor? We just spent $600 to replace the circuit board and the solenoid - hoping to avoid another big bill...


Hi,It is just the circuit problem.Not fuse not motor.From the circuit board to the fan there is no start flow of current passing on to spin or to make it start.Check the flow of volts out of the board.Please do rate the solut ... Air Conditioners

38tdb Carrier infinity 38tdb048301 9 years old stopped cooling. fan motor in outside unit replaced 1 year ago. exterior fan not spinning. last 10 fault codes: ac range error, ac high thermal cutout, ac high press switch, (4 days previous) fc 44 blower com fault, (10 months previous) ac low thermal cutout.


... Air Conditioners

Carrier 38tdb Carrier infinity 38tdb048301 9 years old stopped cooling. fan motor in outside unit replaced 1 year ago. exterior fan not spinning. last 10 fault codes: ac range error, ac high thermal cutout, ac high press switch, (4 days previous) fc 44 blower com fault, (10 months previous) ac low thermal cutout.


... Air Conditioners

I have a suburban lp furnace and duotherm air/heat pump roof unit. duothern thermostat. 20 amp breaker kicked ( reset breaker) & furnace quit. NOW furnace fan comes on but does not light, and the front AC will not work either, when in the COOL position on STAT the unit blows warm air instead of cold. I replaced the Thermostat and a Tech guy checked the board in the furnace and it was OK. He also switched the board from the rear air with the front and nothing changed. Rear air and heat pump works


I'm not sure what the problem may be but you could try calling All\015\012Seasons RV Appliance Parts & Service. There number is\015\0121-800-344-0673 they have helped me in the past. That and there tech\015\012calls are free so it wouldn't hurt ... Dometic Rooftop RV Air Conditioner

I have a comfortmaker unit with heat strips. The blower fan comes in and blows cool air. I have checked voltage at the transformer, and it is producing 24 vac. The contactor for the fan and condenser never pull in so I replaced the defrost control circuit board. Still only blows cool air and the defrost cycle never comes on. I jump 24vac to the coil on contactor and the defrost fan came on and the condenser came on so the fan motor and start/run capacitor are good. Any suggestions.


... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.1391 seconds