Having problems with your Air Conditioners ?

I have a GE room air conditioner and the digital display that normally shows the room temp now has two letters EP and the air conditioner does not cool. What does the EP stand for and how do I get it back to normal.


Answers :

Following are error display codes for GE airconditioner:---
Display Codes:
E1 or EP error:---- Automatic filter clean reminder.
Turn the air conditioner OFF and unplug it. NOTE: The air conditioner must be unplugged for the automatic filter clean timer to reset.
Clean the filter. See the Care and Cleaning section in your use&care manual. After cleaning, replace the filter and plug the air conditioner back in.---.


ER error:--- temperature sensor failure. Call for service.


thanks,keep updated and please accept the solution.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a GE room air conditioner and the digital display that normally shows the room temp now has two letters EP and the air conditioner does not cool. What does the EP stand for and how do I get it back to normal.


Following are error display codes for GE airconditioner:---Display Codes:E1 or EP error:---- Automatic filter clean reminder.Turn the air conditioner OFF and unplug it. NOTE: The air conditioner ... Air Conditioners

GOLDSTAR BG5200ER I HAVE MY AIR CONDITIONER IN THE WINDOW IN MY BACK ROOM. I TURN ON AND I NEED WAIT FOR THE AIR COOL. IS TOO SLOW. MAY BE SOMETHING IS BROKEN OR IS NORMAL COOLING CAPACITY IS 5200


Measure the temp of the air blowing out. It should be 20 degrees lower than the intake air at the filter. If not, we need to dig deeper. ... Goldstar WG5200ER Air Conditioner

My air conditioner will not turn on. (See below for a more detailed description.) I recently bought a used Kenmore Room Air Conditioner Model 580. 76129. It worked well for about a month (running almost continuously, usually on either energy saver or cool). About a week ago, I walked out of my room when the air conditioner was on, and it was off when I walked back in about an hour later. (The display was unlit, and it was not making noise.) The power button still does not work. The outlet


If you have a GFCI plug on A/C unit it may need to be reset at the plug. ... Kenmore 76129 Air Conditioner

My air conditioner blows very hot air out of the back and nice cool air out of the front. Is this normal?


... Windchaser PACR10 Portable Air Conditioner

I have a Lennox CB29M Air Handler with an electric heater, which is used to heat the lower two rooms of my house. The handler unit is located in a mud room right behind the back patio. I'd like to get an air conditioner unit that can mount on the patio that can be hooked up to this air handler, so I can have air and heat in these two rooms. Are there units that are available that can work with this air handler? How hard is the install, and can you recommend anyone in the 19030 area that I can tr


Any of these Lennox dealers can help you choose a compatible HS29 or HP 29 condenser and evaporator coil to match your system.http://www.lennox.com/locate/default.asp ... Air Conditioners

AMCOR Portable Air Conditioner - CF14000E Our portable air conditioner was working fine. I turned it off and was going to move it into another room, it would not turn back on. There was no green light on the LCDI plug. I tried it on different outlets but no green light coming back on.


... Air Conditioners

Hi, thanks. I have a question regarding the portable air conditioner cvp10nc as I am preparing to purchace one. Is the air from the room being cooled recirculated exclusively through the unit and all put back into the room? Or, is some of the air in the room where the where the unit is cooling sent out the exhaust? Also how many amps does this unit draw? Thanks so much Kerry


Hi kerry have tried to look for the model number as mentioned by you hwever was unable to find that on the sharp site however they do have two other models namely CVP10PC and CVP10RC for which i am providing you with the link here you can get whateve ... Sharp CVP10NC Air Conditioner

Sometimes, our furnace will start blowing cold air when it should be blowing hot...I know it is normal that it blows hot air and then will blow cool air as it cools to shut down. This is not what I am talking about. I am talking about while the furnace is blowing hot air to heat, it will quit blowing the hot air and start blowing cold and it it like the air conditioner kicks in. It will then continue running cold air...I usually have to shut the furnance off and when it kicks back on it will


Do you have an automatic change over thermostat? this would switch it from heating to cooling. ... Air Conditioners

I have a Sharp portable room air conditioner model CV-P10NC. The power plug RESET button and TEST button will not click in order to check out the power plug as the unit will not turn on. They did test O.K. at first but the unit would still not come on. Can the power plug back be taken off to check out the fuse inside - or since it is a type of built in circuit breaker maybe it does not have a fuse inside ? The instruction manual states that " This air conditioner uses a fused power plug". The un


The fused9G.F.C.I.) cord you speak of is probably the G.F.C.I. built onto these units by design, can you or someone you know get access inside the unit and :Hot-Wire" the units cord and,bypass the power cord ( Just To Test the Unit)and see if it stay ... Air Conditioners

Replacement Remote I can't find a replacement remote for my Turbo Air Conditioner - Room Air-Conditioner. (Info on Wall Unit - Model of indoor unit TAS-9H, Serial # A09HI02196, Bar Code # C2G5101320) (On the back of the remote - ZHF/LW-15, Rated Voltage 3V.DC) I live in Phoenix, AZ if you can tell me some place local I can get one or order one online. Thanks so much, Robert McDonald


EMAIL: [email protected] for parts / remote controls ... Turboair Air Conditioners

I have a Danby DPAC10030 air conditioner. It was working fine until yesterday, when we moved it to another room. Now it blows cold air for 5 minutes and then the air turns hot. The a/c motor continues to run even though the air is no longer blowing cold air. The current ambient temperature is 25 degrees C and I have the a/c set to cool to 17 degrees C. The timer has been turned off (0:00 on and 0:00 off). I noticed that the hoses (exhaust) feel quite hot. Not sure if that it normal within


Clean you filter and clean the area under the intake duck it will solve your problem ... Air Conditioners

Hi guys, i have a portable air conditioner 9000btu 'ariagel ag90' window) that works great for the first 5 minutes, until gradually the unit makes more and more noise until it shudders quite violently , returns to its normal noise and blows out hot air for 5 minutes. This hot air seems enough to cancel out the cooling it does. then after a while it cools gradually I've read alot about this air con problem, but nothing regarding the gradual noise and shudder. The slide out filter at the back s


This is due to the compressor going into thermal overload, It can be cause by really dirty coils preventing air flow,A restriction in the cap tubes or orafice, Or an over or under charge in the system.The noise is due to the compressor building up to ... Air Conditioners

Problem with Amcor PLM12000E Portable Air Conditioner- system stopped blowing cold air after power outage. Compressor turns on for 3 seconds and then turns off. Blowing out fanned air and room temp air out the back.


You more than likely have a blown relay or fuse ... Air Conditioners

Window air conditioner cools but doesn't dehumidify room. This has been the case since it was new. The unit is tilted down slightly in back as recommended. The room is small. I read that having a unit that is oversized for the room can cause this problem.


Thanks for your question!\015\012I'm sorry that you haven't received an answer yet.\015\012The response rate on FixYa FREE questions is usually over 80%, but sometimes questions go un-answered when:1. the question is unclear, incomp ... Frigidaire Compact Air Conditioner

I have a Coleman Central Air/Heat System. This year, the outside compressor (or whatever it is called) is shutting off within minutes of the air conditioner coming on. This is resulting in the home never cooling down. I can reset the system by shutting the air off inside the home for a few minutes and the outside compressor comes back on, but again, only for a minute or two, and the unit only blows what seems to be room temperature air.


Do you know the devices model. It would help in locateing the manual. also I beleave you have the manual?\015\012\015\012As micromaster already said, check for sleep timer.\015\012\015\012has the system worked fine before has ... Air Conditioners

Our air conditioner seems to be working fine yet t won't blow cold air. Its just room temp air actually feels like you're standing in front of a small fan.


Check outside unit large pipe should be cool or even very cold small pipe should be warm to touch that will eliminate some questions in order to solve problem also check circuit breaker for outdoor unit see if fan on outdooor unit is running an ... Sunbeam Air Conditioners

Cools for few minutes then stop cooling....Hi my unit GE (APH10AA) Air Conditioner, only cools for 10 minutes and then stops then is the fan that runs forever , with out getting to cool again,plus the back of the unit ,the vent takes out lots of VERY HOT AIR, my room will get so hot ,what I can do to fix it? please help


... GE APH10AA Air Conditioner

I recently pruchased the air conditioner and when I turn it on and the air starts to flow it makes a noise (squeeky) for about a minute and then it is gone. Is that normal? also it will not cool the room past 70degrees?


... LG LP0711WNR Portable Air Conditioner

My air conditioner evaporator housing appears to be clogged. The normal drain line goes to the sewer. When it is not draining properly, a back-up drain line coming from the same evaporator housing, drains to the pan (below the unit). Then the pan drains to a visible outlet on the roof (which signals the home owner that there is a problem). We noticed the roof drain line was draining last weekend, so we checked the pan under the evaporator unit, and it had water in it (which is not normal


If you are sure that it's not the line, you are going to need to get to the drain pan to clean it. Take the cover off (with power off) to access it. It's not that muchto get to it. Use a drill and a socket. Once you get in there you will ... Air Conditioners

I have a fujitsu ar-ry3 and the operation and timer light keep flashing and the air conditioner is only blowing out warm air, how do I get it back to normal?!


... Fujitsu 36CS Air Conditioner

My Sharp floor-standing air conditioner (black, from Home Depot) suddenly stopped working. When I press the power button, the Operation light comes on and air blows, vents move, for less than one minute, then the whole unit shuts itself back off. It will do this over and over. An appliance repairman who would not come look at my unit said that it sounds like an electrical problem. What can we do? No one will service this in our area (Orange County, CA)


... Sharp CV-P09FX Air Conditioner

Hi, I have 2 Toshiba compressors (PH170X & PH160X), New, for air conditioners. Can they be used to pump air? Does this cause any problems? Do they need to be filled with oil, and if so how much? They have 3 electrical connections on top marked S / R & C. I believe R is for Red - Active, what do the other letters stand for? I would appreciate any assistance. Regads Helmut.


No they will not pump air. the oil in the compressor circulates in the freon, the freon also cools the compressor. these run on 230 volts c-common r-run, and s- start from a capacitor. Sell them to a dealer ... Air Conditioners

I purchased a commercial cool room air conditioner by Haier (7000 BTU) and I set it up and turned it on and used the remote and everything worked accordingly. I came back in the room to adjust the settings and the remote would not work. I changed the batteries (though they were just out of the package 3 hours ago) and was able to adjust one setting and the remote would no longer work. Unfortunately with this model, all settings except the on/off switch are on the remote. Please help!


I am assuming that this is the same thread that I just answered only with a different title. ... Air Conditioners

Goldstar Room Air Conditioner problem...


It sounds to me like you have a weak run capacitor on the compressor. This will cause the compressor to be able to run for a short period, but it will be overworking itself to compensate for the weak capacitor. It overheats, shuts off to protect its ... Air Conditioners

My air conditioner after reaching temp cuts out but then when it cuts back in runs freezing for a while before it warms again do i have a problem or is this normal?


Check your filter, clean it, and clean the coils behind the filter. ... Amana Comfort Zone 18M33PCEH Air Conditioner