Having problems with your Air Conditioners ?

I have a wall mounted Kenmore 21,000 BTU/hr air conditioner model 106.8752192. The compressor and cooling portion of the air conditoner works fine. However, the blower motor bearing appears to be going bad. The noise at ''LO'' speed with the compressor off is gradually getting worse. Is it repairable? What is the estimated repair cost?


Answers :

Sure it is repairable, in fact it's a relatively simple process if you are familiar with electronic devices and handy with tools.
\015\012
\015\012You will need to simply replace the blower motor and capacitor.
\015\012
\015\012Most motors for those units run anywhere from 25 to 55 bucks, and the capacitors are typically 5 to 15 dollars if they do not come with the motor.
\015\012
\015\012There are usually 3 to 5 wires to the motor and two wires to the capacitor.
\015\012
\015\012If you pay a repairman you can expect a bill ranging from $175 to $225
Ck the motor to make sure one of the fan csges hasn't come loose. If it is yhe motor it can be replace. Best to call an appliance store, parts store for the price. but I would guesstimate around 45,00 for the motor and labor , can't guess. Good luck, Ned.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a wall mounted Kenmore 21,000 BTU/hr air conditioner model 106.8752192. The compressor and cooling portion of the air conditoner works fine. However, the blower motor bearing appears to be going bad. The noise at ''LO'' speed with the compressor off is gradually getting worse. Is it repairable? What is the estimated repair cost?


Sure it is repairable, in fact it's a relatively simple process if you are familiar with electronic devices and handy with tools.\015\012\015\012You will need to simply replace the blower motor and capacitor.\015\012\015\012Mo ... Air Conditioners

I have a tempstar 2000 heat pump approx. 6yrs.We have the compressor go bad 3 different times and replaced by the original installer.Now Action Air of Florida says they don,t know why so many compressors are going bad and now want to replace the a/c heat pump unit . HELP


No compressors don't just go bad first of all is unit a split system or a package unit.if its a split system need to make sure copper from evap.coil to outdoor unit sized properly.next need to make sure your ductwork is sized properly undersized duct ... Air Conditioners

Hi i recently purchased a used convair portable supacool 9 air conditioner the first time i switched it on it appeared to work ok but the next time i turned it on it is working on normal fan mode but when i turn it to air conditioner mode it is doing exactly the same as on normal fan mode the compressor does not appear to be working and is not making the extra noise that it was the first time i have tryed all the switchs including the thermostat but there is only a very simple to use set up any


... Convair Portable Air Conditioner

I've made some additional checks in the air conditioner. After checking the capacitor, it appears to be okay. The compressor input winding measures 2.6 ohms. The starter assist unit when measured disconnected from across the capacitor input to the compressor reads 37.5 ohms. The capacitor readings were more than 10 megohms. What would a normal compressor input resistance read and what is the posssiblity that this input starting device is bad?? Thanks, Jim


... Fedders A6Q10F2B Q Chassis Room Air Conditioner

Hi,I am really hoping to find someone to help me if possible. I have a one year old carrier infinity 4ton 17seer condenser and a 5ton variable speed air handler. I has worked fine but now i am getting a SYSTEM MALFUNCTION on the thermistat. When this message appears the air handler continues to blow and only the fan on the condenser continues to run but NOT the compressor so it is not cooling. At times it begins cooling again but then later stops cooling and shows the same malfunstion message. I


Hi,\015\012If this si what I am thinking it is, it will be very hard to find and prove.... \015\012The compressor windings have aflat spot and if the motor stops at the right place it will not atart. The voltage goes way up and kicks out ... Air Conditioners

For the past two days I have had to reset the main circuit breaker for the outside unit. It appears to be running fine now. I'm just wondering is this an indication of the compressor about to go bad, overuse due to the hot weather we're having or the compressor overheating and becoming temporarily "stuck" until it cools down? I haven been able to check the current draw with my amprobe yet, and the thermostat has a "time-out" feature so I don't think the problem is "short-cycling" Just fishin


Bill, first thing, make sure the outdoor coil isn't stopped up with dirt. This will cause the compressor to overheat and possibly trip the breaker. If you you can check the amp draw that would be good. Look on the data tag on the outside unit and lo ... GE Air Conditioners

Rooftop air, when stat calls for cooling, fan comes on but no compressor. If I switch the stat of & on a couple of time manually, the fan and compressor both come on. Does this sound like the start relay going bad?


Good place to start checking for voltage, in and out of relay when triggered. ( careful, if not experienced with electrical, you have capacitors nearby that can zap you real bad if not familiar with them.) ... Dometic Rooftop RV Air Conditioner

Problem I turned on my air conditioner this spring. I turned the switch to cool on and the air conditioner fan not going. I took cover off and got new capacitator didn't work. I took fan motor into electric shop and checked out fine. When I turn switch on the contact switch engages and there is a humming noise. But the fan does not work. the compressor doesn't start up. The model is at least 10 years old. How do we tell what the SER rating is?


Hi,\015\012There are two things to check....\015\012\015\012Do you have power coming into the contactor???\015\012\015\012Do you have power coming out of the contactor???\015\012\015\012If you have power goin ... Air Conditioners

Hi guys, i have a portable air conditioner 9000btu 'ariagel ag90' window) that works great for the first 5 minutes, until gradually the unit makes more and more noise until it shudders quite violently , returns to its normal noise and blows out hot air for 5 minutes. This hot air seems enough to cancel out the cooling it does. then after a while it cools gradually I've read alot about this air con problem, but nothing regarding the gradual noise and shudder. The slide out filter at the back s


This is due to the compressor going into thermal overload, It can be cause by really dirty coils preventing air flow,A restriction in the cap tubes or orafice, Or an over or under charge in the system.The noise is due to the compressor building up to ... Air Conditioners

I have a Carrier 5 ton Air Conditioner -five years old. I turn on the thermostat and the blower comes on in the house then the compressor engages, but the fan does start. I can manuelly, start outside fan by using a long screw driver to turn the blades. Then the fan begins to turn slowly until it reach a faster speed. But I do not beleive that the fan is turning as fast as it use to. I go back into the house and after 15 to 20 minutes the temperture has not dropped. It apprears to stay a th


... Carrier 38CKC030 Air Conditioner

My Goodman air handler RELAY, ELECTRONIC BLOWER TIME DELAY makes a clicking noise 4 or 5 five cycles (about 10+ Sec delay ) before the squirrel cage fan will come/stay on. I have reset the unit by switch it off for 5 minutes then back on and it worked for a week but now it makes the outside compressor go on and off the same number of cycles before it comes on. Do I need a new board or can the capacitor cause this problem? Help it's hot in Phoenix!


When this happens turn off power and feel motor if hot capicitor i dont think this board cost much but if it does you can get a fan sequenseing stack switch to repace the board with ... Air Conditioners

What causes the air conditoner to vibrate? will run okay for up to an hour, then starts vibrating on high setting. On low setting it's not as bad, but if you feel the coach side, you can feel a vibration. after several hours it makes the same vibrating noise that it does on high. turing it off for a few minutes, seems to make it go away for a while.


Take the covers off and look for dirt dobers nest, they are made of mud like stuf. spray some water threw a squart bottle use needle nose and a screw driver to bust them. this hapend to my home and motor home.... bill \015\012ps might be some o ... Dometic Rooftop RV Air Conditioner

I have a 2001 Duo-Therm by Dometic RV Air Conditioner. Recently It sounds like a bearing is going out. Sometimes barely audible, sometimes more so. I have taken the shroud off, Cleaned the fins, checked all nuts and bolts. but we still hear the noise. Can it be anything else but the motor? Thanks Larry [email protected]


See if u can squirt some solvent into the bearings when noise is apparent,of noise changes case solved. ... Dometic Rooftop RV Air Conditioner

We have an LG single split wall mount room air conditioner which was installed in 1999. Today it started making some strange noises like a bearing rattle. We turned it off and on and then it seemed alright again. We then decided to clean the filters which hadn't been done for awhile. After putting them back, the unit won't start again. I try to start it with the remote but nothing happens. It appears to be completely dead. I've checked the house power which seems to be ok. Any ideas on w


The bearing rattle you heard was the compressor going out. Because the compressor is a sealed unit, the only way to repair it is to replace it with a new compressor. It may be cheaper to buy a brand new A/C vs. buying a replacement compressor. ... LG LSC121PMA Split System Air Conditioner

I have an LG model # LWHD1006RY6 window air conditioner, 10,000 btu. It has stopped functioning. The temp display is blinking at "73", (the temp setting we had selected); and there is a low volume, high pitched, rapid beeping noise that coincides with the flashing of the temp numbers. Beep and flash frequency is approx. every 1/2 second. Unit compressor and fan do not appear to attempt to run. What's wrong?


Sounds like the compressor or fan is stuck to me or it's out of refrigerant and won't run due to past problem with the compressor or fan detected, causing the alarm.\015\012\015\012 ... Air Conditioners

I have an air exchange system in my house. I also have a dehumidifie set up with it to remove the humidity in my house. I want to make sure he set up the system correctly. He has the fresh air going into the air exchange and it ducts out to a "T" duct. fresh air goes to the house and also goes to the dehumidifier. the dehumidified air goes to the air exchange to a "T" duct that is mixed with the stale air from the house and is connected to the air exchange that appears to go through the air ex


Hello. Reading your description of the air flow patterns, it appears that you have good reason to be questioning this installation. All of the dehumidified air should circulate through the house. I recommend that you contact the company that insta ... Air Conditioners

I have a AMANA PTh153B50AE (PTAC unit). The air conditioner works fine. It is when I turn on my heater and it does not get warm. It just blows cold air. I have looked at the board and it appears that there are no bad spots on the board from where it had burnt. It appears that it may have a manual heater reset button. I am not sure if that will work but I can;t find the reset button. I am wondering if my heat pump has gone bad. Any help would be appreciated. Thank you.


I have the same problem, and I found the manual reset inside the unit. Turn the power off, and unplug the unit. Remove the outer cover of the unit ( inside cover ) , and remove the 2 screws holding the " wire mesh " in the front of the cover. Pul ... Amana PTH153B50AE Air Conditioner

Compressor I have a air condition unit that blows out cold air for a little while and then the air in neither cold nor hot. I had someone come and check it out and they said the compressor was bad. Is that really the problem or could it be something else? The model I have is Intertherm T3RC-042K. I just don't want to have to spend that much money on fixing the compressor and that is not the problem. If it is the problem, is it something that can be done yourself or does a professional need to do


If the unit does blow out cold air for a few minuets then quits it could be a low pressure cut out that will turn off the compressor because the unit is low charged mening there is a leak in the sealed system i would get a second opinion and show th ... Intertherm P3RA-042K Air Conditioner

TCL Split air conditioning with outdoor compressor noise


... Air Conditioners

My recently May 3rd, 2010 purchased LG LWHD1009R Air Conditioner runs very well and cools great. Noise is not bad at lowest fan setting which is all I need really. My only complaint is the rattle buzzing type noise coming from the Air Intake or the Inlet Grille in the front of the AC. When you lower it the noise and rattle stop and the AC keeps running great. When I put it back up and connect both sides the rattle returns. I notice that if I put it back up but only connect one of the 2 prongs


... LG LWHD1009R Air Conditioner

I have a Trane a/c that is 2 years old , a 16xli with variable speed and since it has been installed it never seems to get enough air flow throughout the house , it seems like it stays in low speed is there setting to adjust to go to higher speed for more air flow?


;Most variable speed furnaces have dip switch setting on the circuit board that must be set to match the tonage of the a-c. there may be a diagram on the furnace door or in the installation manual. ... Air Conditioners

I have a air compressor that I know the fan is bad in the outside unit. The compressor is not turning on. Yesterday the only way that the fan would run is with a push, now today it won't run at all. If the fan is not at full strength, will the compressor turn on. I want to know if I need a new air conditoner or is there hope in fixing this unit...


There is definitely hope in fixing this one as long as its just the fan not working. Carrier can easily fix it for you if you want. If you are looking for any more specific information, I would be glad to help but I will need the model number of the ... Carrier Air Conditioners

2007 Hyunda Sonata air conditioner is blowing hot air. We checked all of the fuses and it didn't make a difference. Checked refriderant level and it is reading too high. Auto store said if the compressor it not on it will read too high. Compressor will not kick on but there was no noise or anything indicating that the compressor went out. Help!! It is too hot for this!


... Air Conditioners

My central AC is not blowing any air through the vents , the air handler is going the outside condenser is going but no air circulation only a small amount in the bathroom no other place.How can I jump the thermostat out to see if that section of the thermostat is bad. I have a White Rogers S.P.D.T. CLG 1.5 Amps. Max MTG: .15 to 1.2 Amps Max. 30 Volts A.C. TYPE 1F56W-444 . LR27935 0321 Class 2 Rev. D . How can I jump this out to see if the fan section is activating the system. I want to see


Check for fan blade obstruction, possibly something binding up the blades of the fan stopping your air circulation, also the duct work may have come loose from the main air supply register, dropping off air to the rooms, it could be something as simp ... Air Conditioners

Compressor noise goodman 3ton 15 seer heatpump model gph3615m41 the compressor is make a continous laboring noise and it's loud.is it a bad valve or the compressor itself, need help


I the compressor is bad it will draw high amps. If the amps are ok then i would look at the valve. ... Goodman CLQ36AR49 Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific