Having problems with your Air Conditioners ?

Conditioner fan runs but compresser shuts off after only a few minutes and doesnt turn back on.sometimes if i tap the side of the unit the compresser turns on but only to shut off later and not turn back on by itself. danby window model DAC5088M


Answers :

From your description, seems like compressor is seizing when hot, tapping it shakes the piston loose then it seizes up again after a while.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Conditioner fan runs but compresser shuts off after only a few minutes and doesnt turn back on.sometimes if i tap the side of the unit the compresser turns on but only to shut off later and not turn back on by itself. danby window model DAC5088M


From your description, seems like compressor is seizing when hot, tapping it shakes the piston loose then it seizes up again after a while. ... EMI EHW 18000 Air Conditioner

I have a Dometic rooftop Air conditioner in my RV When I turn it to low medium or high the fan run the same speed and when I turn it to AC it will run for about 5 min then the fan will shut off but the compressor keeps running I turn it off for a min or so and everythings comes back on. Turn it to the fan only side and the fan will run for 5 min then shut off a min later it comes back on then back off and on in fan only side.


Bad fan motor I suspect The windings are bad causing the motor to over heat sending the motor into thermal overload. would suggest the replacement of motor. Good Luck on repairs\015\012\015\012Dave ... Dometic Rooftop RV Air Conditioner

My unit is 4 years old. I always turn it off when I leave for work in the am and turn it back on when I get home in the pm. Last night I turned it on at 7:30pm. When I went to the front of the house about 45 minutes later, I noticed the unit outside was trying to turn on but would immediately turn off. I checked the breakers in the garage, turned them off and back on but still had the same problem. The fan inside the house is running but unit outside will not kick on. I looked for a magic


It could be a few things.. It could be the capacitor - which the most economical to replace first..\015\012\015\012If you are not really very mechanically inclined - get a trained pro to come out.. It is very dag ... Air Conditioners

Our air conditioner came on by itself this morning. we have been unable to turn it off all day and we are still unable to turn it off. we did however have a wee bit of luck this evening, when we pushed the off button the air conditioner turned off then about 5 seconds later it turned itself back on again. please help as its not even running cool air and it has been 40 deg today and is still very humid tonight and my 2 year old son is having major difficulty sleeping!!


Hi,\012\012Please check the auto programmed ON/OFF on your remote commander. May be the auto programming is running that run your air conditioner all time without stop. Check also your temperature setting.\012To hard reset your remote , remove ... Air Conditioners

Dry pad I went up to check the MasterCool to make sure the belt was on properly, because it was making a small thump when it turned on. I turned the circuit breakers for pump and fan off at cooler box. Belt was fine. Didn't notice if the pad was wet or not, but it had been nice and cold just before I went up on the roof. Turned the circuit breakers on, came back downstairs and noticed about 4 hours later that I wasn't getting any cool air at all. What could I have done? (I did bring the pu


... Mastercool 67680 Evaporative Cooler Air Conditioner

Our Carrier 38ckc036350 is not working - the outdoor unit was very hot to the touch and will not turn on -turned it off at the thermostat - later when the unit cooled down turned it back on via the thermostat and it would start to kick on, but then stop - no breakers were thrown. Unit will be 7 years old in the middle of July '10 and am wondering: 1. what could the problem be & 2. will any of this be under warranty?


The first thing I would check is to see the condensing coil is clean. Take a garden house and wash it thoroughly. If it is severely clogged you may need to remove the top and clean it with water pressure blowing from the inside out. This may stop the ... Carrier 38CKC036 Air Conditioner

Our Carrier central air is unresponsive, nothing at all, no noises, air handler and condenser unit will not turn on, please help me before I lose more weight in my 150 degree attic. The serial # for the air handler is 0695803341 and the product # on AH is FB4ANF030000ACAA / we only have central air, system is not connected to any heat source Early sunday morning I turned the T stat to the off position, when i came home a few hours later I turned it back to the on position and nothing at all, no


I think you need to slow down and start fresh. \0121) You have 115v at Transformer-You are reading from Red to White\012 on windings?\012\0122) If that checked out OK are you reading 24v out of Transformer?\0123) If ... Air Conditioners

I have a GE airconditioner i turn it on then it shuts off then it goes back on seconds later


Low gas pressure shutdown. Call a technician ... GE Zoneline AZ55H07D Air Conditioner

My ge ac ASQ18DKS1 trips the gfci on the power cord at all different times.runs 5-10 min then maybe 2-3 hr even b4 the comp kicks on. i turn power off at controls and when i come back later to turn it


... GE Air Conditioners

For some reason after I switched it off last night then switched it back on some time later it didn't work. It looks like it is going to start say i put it on 23 there is a star and a drip under it next to the 23 and next to that the circle with a vertical line through it. The bottom comes down like it is going to blow air and then it suddnely goes back up after about 1 minute and displays CH then 05. I have done everything I can think of including turning it off at the mains for at least 10 min


Hi, CH05 means a error code.This error code means there is a communication error between the indoor unit and the out door unit.this is usually caused by wiring errors condensate pumps connected to the inter-connecting cable.The communication ... LG Art Cool LA121HNP Split System Air Conditioner

AC Condenser motor will stop at 1pm but inside unit is still running but no AC. If I turn the AC unit breaker unit off and then an hour later turn it back on. The unit runs fine all day until 1pm. Had a tech out and he checked the system and it's fine. He said I may have a thermostat problem and he would need to see the manual. My theromastat is programable (Carrier, 4 zone, Comfort II) with 3 remote temp sensors. How do I troubleshoot this?


I am having the same problem. The unit out side is off and I can have the thermostat off and it keeps blowing in the house. The weird thing is it turns it self on and off inside every 15 sec or so.. How can I stop this or why is it doing it? ... Carrier 38CKC060 Air Conditioner

My LG LSN182HE will not turn on using remote or the one button. I check fuses and breaker and they are fine. Power is coming into the inside unit but nothing happens when I push the power button. I turned it on AC mode and it started running. When I went back into the room later the unit was off.


You should check the condition of capacitor, there may be a small transformer inside the unit, check it for 24vac. If your problem still exists then you can contact with LG technical support at ... LG LS-K2430HL Heat Cool Mini Split Air Conditioner

My thermostat is set on 72....but shows it is 76 in the house. I shut it off yesterday in case it was freezing up. 2 hours later, turned it back on and it cooled great the rest of the evening. I woke up at 3:00 am this morning and was doing the same thing. I shut it off for several hours, now has cool air blowing, but not as cool as it should and still shows 76. Cool flashing on the thermostat.


It sounds as thought the coils on the unit need to be cleaned, make sure it is draining, if it still freezes up after cleaning coils and checking for draining then the unit has a leak and needs to fixed/charged. Hope this helps tim ... Air Conditioners

I have a Fedders portable air conditioner Model AEP09D2B. I have been using the heater feature at night lately. I turned it off when I got up this morning. About an hour later, it began to beep and the Warning light was blinking. I unplugged it and went to work. When I got home, I plugged it back in. The Warning light resumed blinking and the unit began to beep again.


Do you have the owner's manual for your unit to see what the warning light is trying to tell you? I looked all over to down load one from the net to see what it meant and I can't find one.It may be a simple as the filter needing cleaned a ... Fedders AEP09D2BCOM Portable Air Conditioner

I have central heat and air system, my problem is when in heat it runs for 10-15 min. turns off and about 20 seconds later starts back up. It shts off before hiting its tstat. temp.


If this is a gas furnace and you have a cooling coil on top then you could have a dirty coil. Also a dirty air filter can do this. I have also found dirty blower wheels. The gas furnaces have a high limit to prevent the heat exchanger from over heati ... Bryant 463AAC008BA Air Conditioner

Was working fine all day. shut it off for a whlle and later it wouldnt turn back on. pushed the test and reset button on the outlet cord but that didnt do anything either.


... NewAir AC-12000E Portable Air Conditioner

I changed my fan motor and squirl cage blower hooked all wires back like they were fan is not turning fast so the compresser is heating up. the old motor the motor mounts went out that why i changed it


If you have changed the motor, I assume that the RPM is the same as the motor you have removed.?\015\012Check the rotation of the new motor, if you have it turning in the wrong direction, it does not matter how fast it turns, it wi ... Dometic Rooftop RV Air Conditioner

Installed Altura 56" fan, worked fine until a few days later when we added the light fixture to it. Worked for about 10 minutes, then fan stopped and we can't get it to turn back on. Light still works. Seems as if something burned out.


Yes you have overloaded the paralleled, relay contacts and they have burnt out, or tripped the protection circuit inside the actual fan electronics. This usually wrecks the electronics, and requires replacement. However replacement parts are ONLY av ... Air Conditioners

I have a goodman cental air that the compresser will not turn on unless you manually push in the contact on the 24 volt thermostat coil. I'm not sure how it's supposed work but i think there should be 24 volts out of one side of the coil to the thermostat and back. I don't have voltage on either side. Does this indicate a bad coil?


You need to check for 24V across the coil.The thermostat is nothing more than a switch which closes the Y terminal to the R terminal and allowing the 24V to be fed from the transformer to the contactor coil and thus turning the syst ... Goodman Air Conditioners

At 30,000 miles my then 8 or 9 month old chevy 2500hd 4wd pickup truck air conditioning started blowing hot air on the driver side (the passenger side was still cold). I turned the truck off and back on and it began blowing normally for a few days and then it would do it again. A year or so later the heat on the driver side went out totally (passenger side worked properly). So now the driver side blows cold air constantly. A few months after that the blower quit working all together. Now at 185,


What year truck is this? This is actually a very very common problem on those chevy trucks. Most times it is the door blend actuator that has failed. and the default for this failure is driver side blowing hot. There are a million posts out there on ... Air Conditioners

My Duo-Therm RV roof-top a/c unit continues to come on and off when the system is turned off. No air blows, just the compressor runs for about a minute then shuts off. About 5 minutes later, it comes back on and does the same thing. Again, let me stress, the system is in the OFF mode.


Hi,The liquid line solenoid valve is bad and is allowing just a bit of refrigerant through it after it shuts off and the compressor pumps down....this causes the pressure to rise a gain and then the compressor comes on to pump down again. ... Air Conditioners

We have a 1F89-11 White Rodgers Thermastat and the Malfunction light stays on even when reset. Turned off power to unit but about 1 minutes later malfunctino light came back on. Heating system seems to be working correctly


... Air Conditioners

My air conditioner will not turn on. (See below for a more detailed description.) I recently bought a used Kenmore Room Air Conditioner Model 580. 76129. It worked well for about a month (running almost continuously, usually on either energy saver or cool). About a week ago, I walked out of my room when the air conditioner was on, and it was off when I walked back in about an hour later. (The display was unlit, and it was not making noise.) The power button still does not work. The outlet


If you have a GFCI plug on A/C unit it may need to be reset at the plug. ... Kenmore 76129 Air Conditioner

My Honeywell T87F Thermostat doesn't shut the A/C off when the temp in the room gets down to the Thermostat setting. I have it set on COOL and AUTO. I have to shut the A/C off; then later turn it back on as it gets warmer again.


Remove the thermostat and disconnect the r and y connection. If the A/C continues to run ya got a short in the wiring somewhere. If it shuts down then your tstat is hooped. ... Honeywell Air Conditioners

I have a honeywell PA404A pressure control switch on my home gas steam heating system. I'm having a problem with the switch turning off the system. It will only come back on if I turn the top screw all the way out, then back down to approx 5psi. At this point the heat will turn on but when the thermostat shuts down the system it will not turn back on when calling for heat unless I adjust the screw again. Also, the switch will only turn on the system when set at 5 on the dial on the inside. Any i


This may be caused by accumulation of sludge in the steam trap (the looped tube that connects the pressuretrol unit to the boiler). the sludge restricts the pressure from reaching the diaphragm in the pressuretrol unit. So it gets a false reading. ... Air Conditioners