Having problems with your Air Conditioners ?

I have a DuoTherm BriskAIr 13.5K BTU. The Dometic thermostat also controls my HydroFlame 8531-IV furnace. This morning, the furnace would not come on. I checked the wiring and there is no voltage at the thermostat blue wire on the furnace. If I jump 12 volts to the thermostat blue wire, the furnace works normally. Replaced thermostat; no change. I hear something clicking in the air conditioner unit when I switch the thermostat to furnace mode. I assume the A/C has a relay to control the thermost


Answers :

If you look at control box at roof unit, they usually use a separate set of wires for furnace. See what colors they are attached to at harness to thermostat. Some just follow other harness, and come out at thermostat. (bypass control box) Once you've determined which 2 they are, join them together & see if furnace starts, as it should. If it does, thermostat is faulty. If not, pull outside cover off & check voltages at furnace. I'm guessing by furnace model that your unit is approx 30 ft , but if it's a park model, you may have 24 volt system on furnace or 12 volt. Another way of confirming is to go to back of furnace where air intake grille is inside your unit, and locate 2 blue wires going to furnace & remove whatever wires are attached to them & connect them together. Furnace should start up.
What kind of a thermostat is this? I am assuming that this the standard Analog Dometic Thermostat with the wires that connect to a bar across the top. I'm not sure which blue wire for the furnace you are referring to at the thermostat. The blue wire at the thermostat is the -12VDC wire or ground for the unit. The white wire on the thermostat is the one that calls for heat. The white energizes and the relay on the board makes to connect the two furnace thermostat wires together causing the furnace to fire.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a DuoTherm BriskAIr 13.5K BTU. The Dometic thermostat also controls my HydroFlame 8531-IV furnace. This morning, the furnace would not come on. I checked the wiring and there is no voltage at the thermostat blue wire on the furnace. If I jump 12 volts to the thermostat blue wire, the furnace works normally. Replaced thermostat; no change. I hear something clicking in the air conditioner unit when I switch the thermostat to furnace mode. I assume the A/C has a relay to control the thermost


If you look at control box at roof unit, they usually use a separate set of wires for furnace. See what colors they are attached to at harness to thermostat. Some just follow other harness, and come out at thermostat. (bypass control box) Once you've ... Dometic Rooftop RV Air Conditioner

My ruud deluxe 89 furnace is not working. The fan will work but does not blow hot air. When I move swith to Auto I hear the click, but nothing happens after that. I have changed the filters which were very bad and have changed the batteries to the thermostat. Van you help? I was hoping it was only a fuse or something like that. Im not sure where to find the fuse though. Thanks, Brayn


The directions on mines says to turn the pilot off for 5 min to clear gas out the pipeline. then turn it to the PILOT position and push down while lighting it, then once its lit turn it to ON. ive tried that but its not working. i dont know if im not ... Ruud Air Conditioners

My Carrier brand gas furnace quits working, so I move the thermostat to 50 degrees, it clicks, then clicks at 70 degrees and starts working again, sometimes for one cycle or sometimes for a day or two. Then it quits again. I replaced the thermostat and it still does this, no change. It appears something in the furnace itself is causing the problem. Also, if I switch the power switch off and on, then the furnace starts working again temporarily.


Yes it is the relay that pulls in that turns the furnace on. Sometimes they get carbon build-up on the contacts. I guess the easiest way to describe how to locate the relay is to have someone operate the thermostat and you listen at the furnace for t ... Air Conditioners

I installed a new honeywell rthl111 series in Oct. 2012. I wired the blue wire to the RC because that was how the old thermostat was wired. The heat worked all winter but when I tried to change over to cool nothing would work. I checked the schematics online and realized I should have installed the blue wire to the B. I checked the fuse in the power panel and saw I had blown it. I changed it and rewired the thermostat the correct way. I tried again and still neither the cool or heat will work. A


... Goodman Air Conditioners

Coleman on a 1993 terry. fan and A/C don't respond. You can hear clicks when the thermostat is changed from one mode to the other but no responce from a/c.(the furnace works by the thermostat though) Unir worked for about an hour when we first bought the camper, last week. any ideas? Thanks


Low on freon , low pressure control open.Tom ... Coleman Mach III Air Conditioner

My plan jane evcon thermostat is not wired right. The furnace works fine. The air conditioner will only come on when you push the lever up hotter than it is in the room instead of cool. It will then run, but runs and runs and will not shut off. There are 4 wires, red that is hooked to screw with B by it because the blue wire has a piece of paper on it with a Y and is hooked to the Y screw, white that is hooked to one with W and green wire is hooked to the screw with G. little short red wir


Hi,\015\012Okay....two things to check on...\015\012make sure that the terminals and the wires are matched in the t-stat and the furnace board...R-R Y-Y G-G W-W ....if everything matches up then you have a fried t-stat... What you are say ... Air Conditioners

I have a Rheem Gas Furnace with an old analog thermostat (Wires conneected to terminals R and 4 for the thermostat). I went to install a Rheem digital and programmable thermostat and it indicated that it would not work for that wire configuration (Instructions indicated that the thermostat would not work with wires to the #4 thermostat terminal). Is there a setting on the furnace circuit board I can change, or is there a digital, programmable thermostat one can use on this unit - Model RGDJ 12EA


If you have 2 wire at thermostat Terminals at furnace that the thermostat wire attach to should be R & W if your new thermostat has R & W terminals is should work, an easy thing to remember is the red wire on R the white wire on W. If 4 wire ... Air Conditioners

I have a suburban lp furnace and duotherm air/heat pump roof unit. duothern thermostat. 20 amp breaker kicked ( reset breaker) & furnace quit. NOW furnace fan comes on but does not light, and the front AC will not work either, when in the COOL position on STAT the unit blows warm air instead of cold. I replaced the Thermostat and a Tech guy checked the board in the furnace and it was OK. He also switched the board from the rear air with the front and nothing changed. Rear air and heat pump works


I'm not sure what the problem may be but you could try calling All\015\012Seasons RV Appliance Parts & Service. There number is\015\0121-800-344-0673 they have helped me in the past. That and there tech\015\012calls are free so it wouldn't hurt ... Dometic Rooftop RV Air Conditioner

Bryant furnace I have a Bryant furnance and central air. series 3C-G serial # 44Y 368450 model # 125-394U upflow and model # 125394C down flow. My problem is it is not coming on. the breaker is not tripped, the pilot light is lit, when I turn the thermostat i hear it click but the furnance or central air does not come on to run. Can you help me get it working?


... Air Conditioners

Amana GUIC070A30 furnace won't run. Air conditioning functions but no heat. Reset thermostat, set to heat & bumped up temp to 90F. Thermostat clicks & nothing happens after that. I have covers off unit & with therm set as stated I get a flash (not continuous or pulsed) on the ICM diag LED & I can hear the trans hum. I did the full startup procedure from the manual. Has 115VAC & 24VAC trans working. ICM 3A fuse good. Any suggestions?


Jump a wire between r and w on the board.if it fires its in your tstat\\wire ... Amana Air Conditioners

RTH221 honeywell thermostat install, hooked up blue wire from old thermo that hooked to C to o/b connection on new thermostat no work did I screw something up as old thermo will not work as well now. was not supposed to hook blue wire up I found out later on Internet. any easn fix, blown fuse??? etc. Thanks


Hi,\012maybe a blown fuse if it has one... if not then you blew the transformer...\012Check on the circuit board in the furnace or air handler for a fuse...\012if there isn't one... then you will need to replace the 24v transformer. ... Honeywell Air Conditioners

We had our furnace replace this winter, our air was only about 8 years old and working fine so we didnt change it, well now , the air coming out of the vents are cold, but the condenser NEVER shuts off and the thermostat never reads what it is set on, it stays 2 or more degrees higher, the company that installed the furnace checked the air and said everything is working fine, and leaves me high and dry and HOT... the freon level is good, the pressure reading is good, but the house is hot and the


Hi, if the new furnace they put in did not have the right size coil to match the outdoor unit, it would run all of the time and not cycle off. Lets say if it is a 3 ton condenser, the indoor coil must be a 3 ton coil as well. If they put a 2 !/2 coil ... Air Conditioners

Suburban sf30 rv unit.. I had a new board and limit switch installed. The service tech said it was working. I marked the wires when I removed the unit. I re installed the unit conecting the wires the same as when I removed the unit. I have 2 blue wires, 1yellow and 1 red coming from the furnace. There are 3 thermostat wires 1 grn, 1 wht and 1 red---The power source are 2 solid white wires and 2 blk and wht striped wires, there is power to the unit. I am at a loss as to why it will not work. T


... Dometic Rooftop RV Air Conditioner

Condenser outside Aight,,, so i finally got power to it outstide,, now, to get it to work i had to bypass some wires,,,, from thermostat to furnace and then to outside we wind up with red and white wires.... both hace power,,, now,,, the white connects to and follows a blue wire.... blue wire goes down and inside this white tube lookin thing... this thing is attatched to copper pipe,,, another or possibly same wire comes out,,, thats where the power stops and fail to turn the motor on,,, what is


You could br=e low on r-22. sounds like the thing is a pressure switch ... Ruud UBHC Air Conditioner

I have a white rogers thermostat, it wont click on automatically when it is colder in the house than i have the heat set on. furnace just pops, fan does work and does blow hot air when i turn it to on. i have a digital thermostat. i reset all the programming for it, even turned it off and turned off the furnace with 2 breakers at the bottom of the furnace but still nothing. The furnace is warm like it is trying to kick on


Did you connect the jumper wire to rc---rh on the thermostat? ... Air Conditioners

Hello, I recently purchased a new home which has a Nordyne model # JS58D-060KA air conditioning unit. Both times when the home was appraised and inspected, the AC worked when they provided power via a generator. Now, the standard electrical supply has been turned on and I cannot get any results. When I turn the temperature down on the thermostat I hear something kick-on in the attic above the thermostat but no air. If the thermostat temp is adjusted for heat or is disconnected, whatever is k


... Air Conditioners

I purchased a 1994 5th wheel with a Coleman air conditioner. It had been covered and in storage for 3 years. When I turn on the thermostat, it sounds like its trying to work but quits after a minute or two. I cleaned the filter and I can hear a gurgling sound (maybe coolent?). I'm not sure what to do next. Can you help with any suggestions? Thanks. Lynne PS The furnace uses the same thermostat and it works fine.


Hi roblynne,\015\012It sounds like you may have a fan motor stuck or obstructed. After sitting for awhile the motor can get stuck and it may need some help to free up. If you turn it some by hand it may just start working. Do not have the pow ... Air Conditioners

My gibson furnace is about 8yrs old and it was working fine heat was on yesterday morning but last night it stopped. Changed batteries in thermostat which in new(thermostat) but no heat. Checked the vents and no air was coming out. I took cover off furnace and saw that the red indicator light was blinking once every 3 seconds. what could be the problem??


Hi,Look on the back of the bottom cover... it should tell you what the blinking means...\012Here is a tip that will help you try to figure out why your furnace is not working. ... Gibson Air Conditioners

Im at an rv park, approximately 90 degees in the sun, air was cool for about 2 hours, fan continued to run but no cold air. When I change the thermostat I can hear it click but nothing changes.


Take air filter off , look up inside & see if coils freezing/frosting up when starts to blow warm air.Is this a new unit, and has it always done that or just recently? ... Coleman Mach 15 Air Conditioner

Have atwood furnace and coleman mach thermostat and it would not shut off. I unplugged power to rv and had to hit battery disconnect so that it would stop.waited few minutes...turned on...heat would not come on but blower ran until I had to unplug and start over. Is it my thermostat?Then abut 3 hours later went through the whole process again...heat came on..all well....then heat shut off...blower kept going and could hear clicking noise from furnace, (trying to light) and would not work.


It may be your thermostat, but try this first to see if time delay relay may be sticking. When it won't shut off, turn propane off, and go outside and unscrew the 2 screws that hold your cover on, and lower the cover down. Look straight ahead, attach ... Coleman Mach III Air Conditioner

Recently changed thermostat on gas furnace w/ cent air


Unfortunately, a strick standard does not exist for wire terminals and colors. However, there are "norms" which I will be happy to share with you. \015\012Red - Rh & Rc (Jumpered) \015\012Blue - C\015\012Yellow - Y\015\012 ... Ruud UBHC Air Conditioner

I have a ruud achiever 90 plus furnace. Thermostat is set for 70 degrees. I hear the furnace click on and try to ignite. It does this four times and blower comes on without the furnace igniting. Cold air is coming out of the vents. What is happening to my furnace?


... Air Conditioners

When i turn my a/c (goodman) to auto and to cool, nothing is working.and when you go outside by condenser unit and manually push the relay in it trips the circuit breaker. is there any short somewhere or am i not supposed to do that. also i found a blue wire thats connected to the relay had been caught between the covers that have chafe through. is this wire for a thermostat and had cause something not to work. these wires are connected to a small red & white wire. any info would helpful. th


First stop pushing the contactor in if it tripped the breaker than you have a short and it need to be checked out the small wires are the t-stat wires could have shorted the control tranformer have the system looked at by your hvac people dan ... Goodman Air Conditioners

A Nordyne air handler, model B3BV-030K, with 4 wire thermostat. Thermostat and AC works fine in "cool". Switch it to "heat" and nothing happens.No fan, no heat.(I have built in heat strips -resistors). I jumpered (on the nordyne circuit board-input from thermostat) from R to W. (24 volts from R to W, which should start the heater. Nothing. No relay "click" like when AC comes on. If i jumper R to Y, AC comes on ok. Does this sound like a relay gone bad on the circuit board? Or what? If relay bad,


Do you get heat when you jumper R, G & W? ... Ruud Central System Air Conditioner

First, my thermostat wouldn't shut off either my heat pump or my furnace (it runs both). Thought it was an issue with the thermostat...got a new one. Worked like a charm for 1 day. Now, there is a clicking noise coming from the heat pump - it did it at first when trying to turn it on....now, when it's warmer, it will turn on, then start to do it. Doesn't seem to be putting out hot air now. Any ideas? The thermostat came with a new box that sits inside the ceiling and it's been replaced, bu


Sounds like your unit may be tripping on a pressure switch due to low refrigerant or a dirty outdoor coil. You may be able to look through the cover with a flash light to see if the inside of the outdoor coil is stopped up. Otherwise, you will have ... Dometic Rooftop RV Air Conditioner