Having problems with your Air Conditioners ?

Window Unit - Fan does not come on in high & medium cool modes, works fine in low cool, fan also works


Answers :

Fan motor speed control on the motor itself is out.. Replacement is only option. Good Luck
\015\012
\015\012Dave

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Window Unit - Fan does not come on in high & medium cool modes, works fine in low cool, fan also works


Fan motor speed control on the motor itself is out.. Replacement is only option. Good Luck\015\012\015\012Dave ... Air Conditioners

My bonaire evaporative cooler cycles from high to low fan speeds when set in the cool mode. It works fine at the required speed setting when just the fan (no water) is selected. It also dumps water immediatly the cooling cycle is turned off rather than holding it for about 40Min as it should. Sounds like a controller problem, but I'm not sure if it would be the touch pad or the board up on the roof mounted unit.


... Air Conditioners

I have a 1988 Prowler TT with a Coleman TSR Mach3. I've installed a new blower motor.The fan side works fine on high and low but when i move the selector to High Cool the compressor does not turn on..however when i move the selector to Low Cool the compressor turns on and it cools for a few seconds then locks up..now fan no cool air. Any ideas?? Is there a way to change/add oil to these units? Thanks, Hot in Alabama


... Coleman Mach 15 Air Conditioner

The fan speed in my mini split a/c indoor unit is abnormaly low even when set in High speed mode. This unit also has a powerful mode to raise the speed beyond High for 15 minutes, but it is not working either. I replaced the fan motor, the power supply board and the main board to no avail. Any help will be appreciated.


Please change the fan capacitor,all will be ok afterwards. ... Air Conditioners

This is a heating and cooling through the wall heat pump. It works normally when heating is selected - the heat pump runs and both speeds of the fan blow warm air. But nothing runs when cooling is selected. In other words the unit works normally when "High Heat" or "Low Heat" is selected but nothing runs when "High Cool", "Low Cool" or "Fan Only" is selected. The position of the Fan Cycle Switch has no effect - behavior of the unit is the same in both positions of the Fan Cycle Switch.


You have a bad board or bad switch. I would say board. You can have service tech check this out. There is only so far you can go without knowledge of Controls ad electricity. Russ ... Air Conditioners

Amana PTAC Unit is not producing heat. Fan works fine. can not locate manual reset for heat although a label on the unit says there is one. I have an Amana pth153b35ae ptac unit that the heat will not come on. The compressor will run in the cooling mode but not in heat mode. I verified the switching valve is working and the capacitor seems to be fine as the compressor will run in cooling mode. The thermostats seem to be functional because relays can be heard clearly when changing temperature se


I know this is late but I had to add a solution to this problem since I had the exact same problem and was able to solve it. The probelm is not your control board. On these units, the heat pump compressor will not kick in unless the temperature you ... Amana PTH123B25AJ Heat Pump Air Conditioner

I have a carrier Modle No. 38YXA042300. I am getting an H5 error message on my Thermistat Control. I have run the Fan only mode and the fan in the air handler unit works fine. On the unit when I ingage the manual override, the condener unit and fan motor runs and cools. The unit will not run when I put the Thermidistat on Cool mode. Can you help me. Andrew Construction Mangement Speicalthes, Inc.


On some carriers they have a lock out feature outside to reset shut down power to furnace for 90secs. and then restart ... Air Conditioners

Amana heat pump was working fine. Inside blower still working, outside condenser has 230 at contacts and 24 volts at time delay. unit will run if contacts pushed in by hand. high and low pressure switches are made. not sure about time delay, defrost board or defrost relay. i can by pass all the controls and it operates in cool mode for now. what five devices is most likely to be defective?


Time delay bad Tom ... Air Conditioners

1996 Coleman Model 7333C8876. Have 2 units on our Motor Home one day it was hot so I had both units running controlled by a Electronic Climate Control system. It got cool in the evening so I turned them off. The next day when i fired them both up on high the rear was fine. But the front will only cool on Low. The fan will not run on high and you can hear a slight noise coming from the unit. But the fan will not run on high.


Check to make sure the drain tube is clear. It sounds like the blower fan is dragging in water buil-up. ... Air Conditioners

I have a Coleman Mach and been doing fine. Today I turn it on but won't come on when turned to low fan and compressor hums on low cool. Works fine on high fan and cool. What might be wrong?


It could be the fan switch is not working on low speed or the motor windings are bad on lower speed ... Air Conditioners

I have a duo thermall roof top ac on my trailer. The power comes on for a sec on the cool mode any of the settings (low med high) when it goes off the power lite on the therm. flashes on aand off i thought it was a power problem so hooked up to direct current. still same problem. the fan works fine though.


Call duotherm, they have a series of bad pc boards ... Dometic Rooftop RV Air Conditioner

I have 2 dometic roof top units on a 2002 MH that I recently purchased. 1 of the units only runs on high speed, the stat has a high low switch, the unit cools fine. The second unit, the comp starts, but the fan only hums, the shaft turns fine. I switched the start relay from the other unit, same result. I suspect that the start winding is open, but haven't checked yet. I am not opposed to replacing the unit because of age, condition of roof cover,and suspected cost of parts. Would appreciate any


Hi, unit # 2 sounds as though the run capacitor may be open, shorted, ect.When you say you changed relay, I assume you were talking about the capacitor. If the motor didn't run when you changed it, you do have a bad winding, or open as it just hums. ... Dometic Air Conditioners

Sharp AF-R1108X Thru-Wall/Window Air Conditioner was working fine all summer. The past 2 days were extremely hot out. the unit was working around the clock. the unit was in low cool and keeping up fine. Then it started making beeping noises and going into energy saving mode and cycling the unit on and off constantly and would not allow me to turn it off by using the selector button. I had to unplug the unit to turn it off. I left it off for about ten min. hoping it would reset it self. I turned


... Sharp AF-R1108X Air Conditioner

Front unit high cool and high fan not working


I would recommend you take this unit to an RV service center. The issue could be due to many variables. It could be something as simple as the controller board relay or a low freon level. You may also be able to call a regular home heating and air ... Dometic Rooftop RV Air Conditioner

Unit runs but will not cool. Fanruns fine but when turn dial to cool the compressor kicks in for about a second or two the kicks out. Fan works on cool but it will not produce cool air at any temp setting. I have cleaned filter and removed cometic facing and vacuumed the coil face. It was pretty dirty but after all that still would not cool, Unit is installed in a RV and power is provided from house. Gen4erator is also available for power. Unit is difficult to remove from RV and space to get at


You may need to install a hardstart kit if you can get to the compressor.\012go to your nearest appliance parts store to get the part and the instructions are usually on it. If not ask the parts man.\012\012If this was helpful pleas ... Air Conditioners

Coleman 4803A876 low fan and low cool do not work but high fan and high cool work


... Coleman Mach III Air Conditioner

I have got vulcan evaporative cooling system and the fan has stopped working. It blows air but at very low speed. i checked the unit and can see the fan moving at very low speed. The water pump if working fine though. can any one help. Thanks


Try lubricating the fan brings ... Air Conditioners

I HAVE A 2000 HOLIDAY RAMBLER WITH TWO AIR CONDITIONERS. THE REAR A/C WILL NOT COME ON UNDER ANY MODE (FAN ONLY,HEAT PUMP OR COOL)WHILE IN ZONE 2.WE HAVE BEEN ON 50 AMP SERVICE AND IT STILL DOEN'T WANT TO TURN ON.ZONE 1 (FWD A/C UNIT )WORKS FINE IN ALL MODES.115 VOLT A/C IS AVAILABLE VERIFIED AT THE UNIT CONTROL UNIT.3 AMP FUSE IS OK.ANY IDEAS ON WHAT IS WRONG? PS THE FAN ON THE AFT UNIT TURNS FREELY. STERLING SNOW


Have you tried running both, when plugged in, as well as generator running? What about testing voltages etc at terminals on control boxes, has anyone done that? Just in case this unit is new to you, are you sure there is no extra switch that has to b ... Dometic Rooftop RV Air Conditioner

Great site. I have a Simplicity SPAC 8499-5 Portable Air Conditioner and it was working fine up until yesterday (~2 years old). The unit is running and the fan operational but while the green light for Cool/Dry is illuminated that actually cooling unit for the air conditioner is not kicking in. The system is just blowing air (like in Fan) mode. I have checked the water reservoir and it is empty and placed properly in the unit so the switch is engaged but no AC.


... Air Conditioners

I have a dometic duo-therm high efficiency quick cool roof mounted a/c unit. When I place the the unit on cool All I hear is a click on the unit as if a relay is stuck also when selecting the fan setting from auto to on it is the same sound I'm hearing. Needless to say the unitis not working! What is my problem???


... Dometic Rooftop RV Air Conditioner

I have a Sanyo khs1271 that is about three years old. For the last six months it has been making a high pitch chirping sound in both heating and cooling modes. I suspect the problem is the fan on the indoor unit as the chirping only occurs when the fan speed is on high. So far, the only solution to the problem has been to turn it on quiet mode, which reduces the fan speed and thus makes the unit's ability to heat or cool less effective. Does anyone know how to access the fan on the indoor unit


Hi You can try to check this link it has the user manual.Thankshttp://www.sanyohvac.com/assets/documents/user/Use ... Sanyo Air Conditioners

Hi there I have an lg reverse cycle aircon model LWC122RH-2 and the heating seems to work fine on it at however when I try and put the cool mode on it desn't seem to get very cold and the cool light does not come on also the defrost light doesn't come on but the heat light and the fan light and timer lights all work and come on ...please help


... LG Heat cool Window Air Conditioner

I have a Haier HPRBO7XC7 portable air conditioner that isn't working properly. When I turn the air conditioning mode on, the cooling unit seems to turn on, but then stops after about a minute or so, and the fan just keeps running. The unit is only about a year old. I purchased it last summer, it worked fine and then when I pulled it out the other day, it had this problem. Any suggestions?


... Haier Air Conditioners

Dometic rv aircon quick cool air compressor and fan work fine high and low, but if I just want to use just fan ,turn on fan switch no fan, could this have a relay on control bd . weird


My rv just has on our auto with fan it will cycle with the compressor in auto will run all the time in on as long as you are in cooling ... Dometic Rooftop RV Air Conditioner

I have a 8 years old window ac. It's working quite ok. I just want to know which mode is safer low cool or high cool when humidity is high but temp. is about 32-34 degree celcius. Technican advised me to run in high cool mode for some time n then switch is off, but i want long hr. running in low cool mode which is quite comfortable. Kindly advise.


Its not a mater of safety. Its only a matter of witch is best for you. If you want to maintain the temp then leave it on low temp. If you want to save money then you can switch it to power saver mode on high to bring the temp down. Hope this helps. G ... Air Conditioners