A6414w7b b wall unit gfi plug keep tripping problem: fedders wall unit brand new keep tripping the gfi on its power cord


Answers :

GFI plugs go bad very often if you had a storm in you area. You need to replace the plug. Go to aplliance parts house and they will sell you the new cord. Feed back please.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

A6414w7b b wall unit gfi plug keep tripping problem: fedders wall unit brand new keep tripping the gfi on its power cord


GFI plugs go bad very often if you had a storm in you area. You need to replace the plug. Go to aplliance parts house and they will sell you the new cord. Feed back please. ... Fedders A6D24E7D Wall/Window Air Conditioner

The power cord GFI keeps tripping. I visually inspected inside the unit and nothing seems to be shorted or burned?


Does it run long or on and off. It could be a bad cord, try a diffrent outlet. ... Amana Air Conditioners

Unit keeps tripping breaker everytime i put the power to it. was working fine then began to trip the breaker. power supply cords test okay, but each time i reset breaker the unit comes on for a couple of seconds and then trips the breaker.


Hi, It's drawing too many amps. Could be a shorted wire, bad fan motor, or a bad compressor. It could also be the relay in the outside unit. One side of the relay could not be contacting.I would pull the disconnect outside and look at the co ... AmcorAire UCHW-H24AF2 Split System Air Conditioner

My window unit fell out of the window and hung by the power cord that was still plugged into the wall. I was able to grab the cord and pull it back up. I reattached the power cord and now every time i turn on the power it trips the breaker. is this the shorted power switch where can i get one.


Its most likely is not the switch. It is most likely the cord though. Due to the excess strain on the cord it has probably cut through the rubber coating on the wire and connected to the frame and grounded the hot lead. Fix the cord and ... Frigidaire FAX054P7A Wall/Window Air Conditioner

Need a schematic for a Fedders room AC/Heat unit model # AEY18F7E, S/N CR105425084Y 230/208v, 22.75 AMP. Power cord was removed. Have new power cord, just need to know proper wiring to existing terminal ends in unit. [email protected]


One lead to L-1 and one lead to L-2 or "C" on capacitor depending on your model set up. ... Air Conditioners

I have a model # faa065p7a A/C The power cord burned out with some sparks by the test and reset part. Called frigidaire and they said you could not replace the power cord and had to buy a new unit. This AC is not very old and worked fine. Is this true because I see that power cords are for sale and never heard of the whole unit going bad from the power cord. Did the electronics fry or was I talking to the wrong person? They were not very helpful and just said to buy a new air conditioner.


Hello, i have replaced cords on many window units so yes you can replace the cord. I believe if you go to a online appiliance website they will have the cord you need. I have found this website online with frigidaire parts http://www.repairclinic ... Frigidaire FAC124 wall/Window Air Conditioner

Power Cord keeps tripping because somehow water is in the cord. Tell me why and how this happened? We have a new big one that's 25,000 BTU (I think). Any suggestions on how to fix this? [email protected]


Make sure it is draining correctly in the bottom back. Sometimes the fan sprays the water on the cord.\012\012If this was helpful please rate me.Leo Ponder Appliance-Tyler,Texas ... Frigidaire FAH106N1 Wall/Window Air Conditioner

FUJITSU Air Conditioner Model AST24RGB-W is unable to switch on. Have checked safety switch and fuse on home circuit board and is OK. Power conected to outside unit is on and OK. Remote control has new batteries and display OK. Cleaned remote sensor panels on both remote and wall unit. ISSUE: When pressing the Start/Stop button the signal doesn't seem to be received by the wall unit. There is also no operation light on the Wall Unit. Unit does not turn on


What about the inside unit does it have power going to it. i would check the breaker for the inside unit. ... Air Conditioners

Unable to switch on. Have checked safety switch and fuse on home circuit board - OK Power on outside unit on and OK Remote control has new batteries and display OK Cleaned remote sensor panels on both remote and wall unit ISSUE: When pressing the Start/Stop button the signal doesn't seem to be received by the wall unit. There is also no operation light on the Wall Unit. Unit does not turn on


As per the problem which you mentioned it clearly indicates that problem is with the switch in the wall unit.but you mentioned that you checked the switch and it is OK.\015\012this means that the problem is with the main circuit control board o ... Air Conditioners

The unit will not start using the buttons on the unit or the remote. I removed the power for up to 12 hrs. I pushed the test and reset buttons on the circuit breaker at the wall power cord. I have power by the display panel showing error code E1 I have pushed and held down all of the buttons on the unit. Still will not start and continues to display error E1 This unit was purchased in June 2007.


Replace indoor temp sensor. ... Haier HPR09XC7 Portable Air Conditioner

I have an ACE184XRO window unit. The reset button keeps tripping everytime the unit has reached it's cooling temp. It' used on the power saver control. How can I keep it from tripping the button?


... Whirlpool Window Air Conditioner

Hello, my heat pump is a 4 ton unit, it heats ok but it keeps tripping one of the breakers, the 40 amp cooling breaker. I have put a new thermostate, it keeps running after the breaker is tripped and the outside unit is off. I am thinking the breaker could be bad the other two breaker are 60 amp. do all three need to be 60 amp. Thanks


Hello Jack, \015\012\015\012Let me see if I have this right. Your heat pump keeps triping the breaker that is going to your airhandler. The Heatpump is on its on breaker and can not trip the breaker on your air-handler. However, the 40 am ... Ruud UBHC Air Conditioner

I have a Carrier 38tra048340 ac 4 ton unit outside, heater in attic. Thermostat is Totaline P374-1100. Power went out than back on after a few hours due to vehicle crashing into power pole. AC was running at time of power outage. Power came back on, ac would not come back on. Checked house circuit breakers, none tripped off. Turn ac 40amp breaker and heater 20amp breaker off and back on. Voltage ok. Checked fuse box by ac unit on wall, fuses and voltage ok. Went into hot attic to check for powe


Blank screen sounds like a fried thermosat. Abrupt outages can affect certain types of thermostats. Make a jumper wire and jump across R and G. See if you get any action from anywhere. If a fan or compressor kicks in you know you have a burned out th ... Carrier Air Conditioners

GFI on cord trips out.


Probable cause is a single pole gfi opposed to a double pole gfi.\015\012* Do not use a single pole GFCI ON A MULTI WIRE CIRCUIT, IT WILL NUISANCE TRIP IMMEDIATELY\015\012Use a two pole GFCI circuit breaker on such circuits. ... LG LWHD1800R Wall/Window Air Conditioner

Turned off power to window unit (12,000BTU) but a fan still running. We have to disconnect power cord from wall to shut it down


... Frigidaire FAC124 wall/Window Air Conditioner

I have a colman evcon split unit, I had a guy replace the thermostat (old electronic, new mercury) and everthing worked fine. One week later out side unit stopped and was frosted over on the outside. I can push the contactors on the outside unit and got power. I traced wiring down to transformer. I replaced the transformer with one with a circutbraker built in. When i turn the brakers on the transformer curcuit breaker trips...I followed the wiring on the transformer to the best of my ability, h


Hi, you do have a dead short in the control side of the system. Good that you bought a transformer with the breaker. Most people don't and will smoke several of them. Anyway, it is a split system. If it was iced up, it must be a heat-pump, not gas fi ... Air Conditioners

Ac keeps cutting off have to hit reset button on power cord will run for a while and then cut off only 2 years old it is a 220 power unit thanks for any help


Do you have an ohlm meater ... Air Conditioners

Fedders window model A6Y12F2B "New Unit",,only 10 days in use! Just stopped working No Power To Master Panel Air Conditioner Not Working Fuse Panel/Breaker ok,Outlet ok,,power to plug ok(lights up) Reset button on plug functions normally Master Panel is dead, will not light up, non functioning controls


Take it back to the store. Manufacture defect if it died after only 10 days. Attempting repair or disassembly will probably void warranty. ... Fedders Air Conditioners

My 9 year old Honeywell T8001C has no display. My FAU AC power breaker is not tripped. I tried a new Honeywell RTH2510B and a RTH7500D but the Fan does not come on with either of the new units after waiting 15 minutes even though the heat on is displayed on the screen. The 7500D says there is an option to be battery free (just like the T8001C) but it is not in the Manuals for set up or operation.


... Honeywell Air Conditioners

Have electric out at pool equipment pad. Use Pool Cover pump to syphon water off the cover. I put a new plug on the electrical cord of the pump this past August and it worked great. Just noticed that the GFI is tripped and now trips anytime i attempt to plug the pool pump back into the outlet. I removed the plug and everything inside looks fine.


Sorry to read about your problem, I hope this helps you out.1. GFI's dont like pumps.2. you may have defective motor.3. run a ext cord to a another outlet and see what happens.4. GFI maybe defective..I tried ... Air Conditioners

My coleman Mach Rv air conditioner with built in heat strip keeps tripping it's internal circuit breaker when running for any length of time. Just replaced heat strip with new one experienced same issue. I ended up with the fan continuing to run but only cold air comes out of the vents! When I removed the old unit and reset the circuit breaker it too worked again. Have no idea what is causing this to happen. The airconditing part of unit works just fine??? HELP! Ron


There should be an overload protection device in series with the low voltage wiring(t-stat wiring) Is it resting on the heat strip or too close to it? It is a saftey device to shut off the heat strips if the fan quits or a fire in the heat strip sec ... Coleman Mach III Air Conditioner

Khs0971 wall mt. heat pump ser. 0020171 , have power to cnd. cond. to unit no pwr to controls remote ok new bat. unit sits for hrs. then wks. runs then shuts down next day will start again & quits


... Sanyo Air Conditioners

My FEDDERS air conditioning/ heating through the wall unit won't respond to my remote - the batteries are new and the screen on the unit won't change from " E2 ". Perhaps it is related with the snow? Anyway -- I'm cold!


First you have to confirm if the remote control is defective. Use your cell phone camera to check the remote control transmitter. Using your camera as your eyes point your remote control to camera and "on" your remote control, light should emit in th ... Air Conditioners

The power cord to my ac model #agp18dbg1 was removed and lost. we got a new cord and want to make sure its hooked up properly. when we plug it in it immediatly trips the breaker.


... GE Air Conditioners

I used my portable mastercool about 4 times last summer. Now, neither motor will turn on. It is getting power and I checked to make sure all the connections were good. I could not find a trip on the unit so I am at a loss why a practically new unit would just quit working


If not cleaned out properly at the end of the season rust and scale can make both motors quit. Try unplugging the unit and spinning the blower wheel by hand several time. Then try turning the shaft on the water pump by hand; that may free it up. ... Mastercool Portable Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.1151 seconds