Having problems with your Air Conditioners ?

My air conditioner won't turn on. When thermostat is set to cool, the furnace blower kicks on but the compressor and outdoor fan do not.


Answers :

Sounds like your not getting a low voltage signal to the condenser, if your Air handler is in the attic check your secondary drain pan it might be off on the float switch, if your air handler is in a closet you need to check your float switch, it will have some wires coming out of it. Hope that helps you get started.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

My air conditioner won't turn on. When thermostat is set to cool, the furnace blower kicks on but the compressor and outdoor fan do not.


Sounds like your not getting a low voltage signal to the condenser, if your Air handler is in the attic check your secondary drain pan it might be off on the float switch, if your air handler is in a closet you need to check your float switch, it wil ... Goodman CKL42AR42 Air Conditioner

Hello i have Carrier Weathermaker 38tkb air conditioner unit. It's about 6 years old and when i got home today, the unit itself wasn't working. Although the blower fan in the furnace inside was blowing, the fan on the a/c unit outside was not moving. I can hear a humming sound coming from it and once in a while, you hear it trying to kick in (the lights in the house even dim a bit, which is unusual), but it never kicks in. The top center of the unit is extremely hot to the touch. I've checked


The humming noise and dimming of the lights is an indication something in the outdoor unit is locked up or has failed.Check the capacitor as it may have gone bad. If the capacitor is good, then you either have a failed motor, a failed co ... Air Conditioners

I have a three ton package unit put in october i just changd the indoor fan now the compressor indoor and outdoor blower kick on run for about ten seconds and then kicks out any advice


It should be a warranty issue it would if I in stalled it .Tom ... Goodman CLQ36AR49 Air Conditioner

I have the MR36TQY3f outdoor unit with 2 MW09Y3FM units and 1 MW12Y3FM indoor units! The MW12.. works great and one of the MW9... works great! When I run the 2nd MW9 only (other MW9 & MW12 off)..... the outdoor unit compressor or fan does not come on! If I run all units then ... compressor kicks on runs great, fan runs... lines get cold on the 2 good units ... nothing on 3rd unit... then I turn 2 good units off....and it sounds like the compressor kicks off and the fan will continue to run reall


After looking at the manual for the units, I believe that the system is having trouble with the number of units that you have linked. Here is a portion of the manual about multi system operation>Also link to manual:http://www.fri ... Friedrich MR36TQY3F Split System Air Conditioner

The outdoor fan is turning slow. it sounds like the compressor wants to kick on but it wont. the motor is really hot. what could this be


Sounds like a bad capacitor for your fan motor. You can test that by following the procedure listed below.\012***CAUTION***\012 Anytimeyou are working on or around electricity you run the risk of shock and ordeath. Please con ... Air Conditioners

Compressor problem? My outdoor unit comes on with the fan blowing just fine. Then I hear a buzzing sound for about 2-3 seconds which I believe is the compressor trying to come on. (Incidentally, a couple of lights inside the house seem to dim at the same time that the buzzing sound occurs.) The buzzing sound reoccurs every couple minutes while the outdoor unit fan and the indoor blower both continue to run. I have shut down both the outdoor and indoor units for a couple hours and tried restarti


The buzzing is your compressor trying to start. It is going off on internal overload caused by heating up of the motor windings.If you have an amp meter you could check the amp draw of the comp against the locked rotor amps listed on the tag You cou ... Ruud UBHC Air Conditioner

Lennox Conservator III G16, Furnace, Burners stay lite for 90 seconds; no blower; but exhaust fan runs continuous. If I use a jumper from the white heat wire (including white heat wire) to the green blower wire terminal (removed the green thermostat wire) the blower fan runs (non-stop) & igniter & burners restart every 10 mins. when I remove the jumper (& wire to specs from the thermostat to the furnace) igniter & burners kick on for 90 seconds then nothing on the unit works except the exhaust f


... Air Conditioners

When I set tstat to call for a/c, compressor outside comes on. Blower on furnace does not. When I manually rotate fan limit switch on furnace wall, blower comes on, blows cold air, and then goes off when I release the fan limit switch. I have a Honeywell 83251008a low and high voltage transformer, and Honeywell (I think) limit on off switch. I also noticed the 2 wires coming from the Honeywell Gas regulator are off. They were connected at the onset of the problem. I am not sure where to re


Sorry, you mean gas valve control? when you have only 2 wires, usually it doesnt matter which terminal as there,s no polarity differentiation at that locationYou should never rotate this dial by hand, you will bend the helix inside and fan will not o ... Air Conditioners

I have a 15 year old HVAC system that uses a Carrier Weather Maker 8000 furnace. When we returned from vacation last week, we noticed that the furnace blower motor would not turn on. The A/C compressor and condenser fan would turn on, but not the evaperator/furnace blower fan. I started a component test, but the LED just continuously blinked rapidly. The code associated with this is "Line voltage (115V) polarity reversed or twinning problem. How do I fix this?


The control board seems to be detecting reverse polarity, and my first thought is that the relay contactors are oxidized, but you could also have a bad startup capacitor, and/or control board.\015\012The only reason I say control board is becau ... Air Conditioners

Blower fan motor wont start on carrier package unit air conditioner I have a Carrier 50ZPA042-301TP package unit


... Air Conditioners

Amana gas fired warm air furnace. Blower (fan) works fine when thermostat set simply to "fan". When selector is moved to "heat", burner fires nicely but teh circulatior blower fan does not kick-on. Any suggestions?


Either bad run cap on motor or bad blower motor ... Amana Air Conditioners

I have an Intertherm S3BA-048KA Split AC system which has stopped blowing cold air. Indoor blower is working fine. Outdoor fan is not working. I have reset breakers (indoor/outdoor) without success. I can hear a hum coming from outdoor compressor even when outdoor breaker is in off position. I had a problem with a System Breaker last year at the blower due to condensation leading to internal corrosion of the breaker. I replaced with a "suitable substitute" (same rating), not OEM. Request


First thing I would look at is to make sure you have power at the disconnect 110 coming in on each leg to unit. Second, I would look at the capacitor for obvious bulging or leaking Third I would check to see if the contactor has burnt poi ... Air Conditioners

Akai air conditioner. model. Tem50chsabr fault code e0. Outdoor fan/ compressor not running, indoor fan runs. Any suggestions?


... Air Conditioners

Goodman outdoor a/c unit top fan stopped working while the family was away from home and now the compressor will not turn on. Only thing happening when a/c turned on inside is the indoor unit kicks on and the outdoor top fan begins humming and getting very hot to touch. Unit is only 5-7 years old. It is a Goodman CKL42-1L. Please, anyone with suggestions is appreciated. Definetly do not have money to replace the entire unit at this time.


... Air Conditioners

Furnace will not light burners and blower motor doesn't come on, but exhaust fan comes on immediately when turning furnace on. Turned on A/C to make sure blower operates and it does. The combustion chamber door says there is a red button to reset inside, but the only thing I can find is like a thermistor with maybe a button on it and it is not kicked. What should I try next?


The reset button should be a small round red button that you just push in to reset. If the induced draft motor comes on as soon as thermostat calls for heat then the next thing to check is the ignitor. It may be a hot surface or spark ignitor.It shou ... Air Conditioners

Hyundai HSH 3001BA split air conditioner indoor fan and outdoor fan is running but compressor not running therefore checked compressor only and tested and found running. What could be the problem.


Check to see if the compressor is getting a cooling call. that will determine if it's a control issue or a power issue. ... Air Conditioners

I have a Bryant Air Conditioner 561CJ024-E and a Bryant furnace. The furnace control board is not sending a 24V signal to the outdoor condenser and fan unit. Is it possible to trouble shoot the control board itself or do I need a new control board? All control wiring from thermostat and outdoor condenser looks correct.


... Air Conditioners

Duo therm roof top camper a/c. fan runs but compressor stopped kicking on all of a sudden. replaced both capacitors; getting 110 to compressor but it still wont kick on


Hi,\012Sounds like the compressor is toast...if the caps have been changed and there is voltage there, you have done all you can...replace the compressor or buy new...\012\012heatman101 ... Dometic Rooftop RV Air Conditioner

My frigidaire air conditioner model FAA060p7a will not cool the fan works fine but on cool the compressor does not kick on, if I turn the the temp knob you can hear it click behind the knob like its sensing the temp but its not kicking on the compressor.


Hi,The problem here is the compressor.... it has failed and will not start. You can try to replace the capacitor and see if it will go but most likely the compressor is toast. I t will cost more to replace it then to buy a new unit.\012\0 ... Frigidaire FAA060P7A Air Conditioner

I have a Maytag S3BA-024KA Split System Air Conditioner. I have power to the system indoors and outdoors. The outdoor unit is clean and the Contactor is also clean with power going into it. The compressor is not running. I can push the contactors and the compressor fan will run but it will not operate by itself? Not sure what to do now.


... Air Conditioners

I have a Carrier 5 ton Air Conditioner -five years old. I turn on the thermostat and the blower comes on in the house then the compressor engages, but the fan does start. I can manuelly, start outside fan by using a long screw driver to turn the blades. Then the fan begins to turn slowly until it reach a faster speed. But I do not beleive that the fan is turning as fast as it use to. I go back into the house and after 15 to 20 minutes the temperture has not dropped. It apprears to stay a th


... Carrier 38CKC030 Air Conditioner

I have a white rogers thermostat, it wont click on automatically when it is colder in the house than i have the heat set on. furnace just pops, fan does work and does blow hot air when i turn it to on. i have a digital thermostat. i reset all the programming for it, even turned it off and turned off the furnace with 2 breakers at the bottom of the furnace but still nothing. The furnace is warm like it is trying to kick on


Did you connect the jumper wire to rc---rh on the thermostat? ... Air Conditioners

Have a 1/2 horsepower furnace blower motor that will not kick on when it is suppose to the fan on the blower makes a loud buzzing noise. Could it be sticking or a bad capacitator? At times I may put my hand in the blower and spin it to get it going.


Hello, sounds like you capacitor is bad and needs to be replaced. ... Air Conditioners

The outside blower fan stopped working.... i diagnosed it was bad bc i had voltage right to the fan and nothing.... i am however able to use direct electricity from wall plug and the capacitor to get it to run but it runs very how...100deg C... and smells awefull... so i rewired it back into sequence with the relay on the main board and again i have voltage when the compressor kicks on ..... but no fan movement... also i have no voltage when checking power leg to neutral leg.... but power to gro


... Haier CPN12XH9 Portable Air Conditioner

Recently replaced blower wheel and blower wheel motor mounts,that problem was solved but now fan motor for the compressor runs non stop-wont shutoff except by breaker box.also changed thermostat at the same time.have i inadvertinly placed the wrong wire terminal in the wrong recepticle in either the blower motor or thermostat? If so,which one and where?How can it be fixed?The unit is a 1973 coleman evcon.


First question first, NO! this is a simple problem and a common one to fix, just change out the outside contactor coil, the contactor has a thin layer of silver on them to prevent them from arching and sticking together, over time this thin layer b ... Air Conditioners